6. Optical Specifications

6.1. Laser Scanning Specification

Parameter Specification Unit
Light-emitting Element Red laser diode -
Emission Wavelength 650 ±10 (25° C) nm
Light Output 1.0 or less mW
Scanning Method Bi-directional scanning -
Scanning Speed 100 ±20 scans/s
Scan angle: 54 ±5 ° Scan Angle
Effective scan angle: 44 (Min) °

6.2. Laser Scanning Standard

6.2.1. Laser Scanning Tilt
Laser scanning tilt is the vertical difference between both ends of a laser scan
line. Measure it in the middle of the laser scan line.
Up to 1.2 degrees angle in vertical direction from the scan origin (mirror
motor).
Up to 3.1 mm at 150 mm from the scan origin.
6.2.2. Scanning Curvature
The maximum difference between the laser scan line and the line between both
ends of the laser scan line. Measure it in the middle of the laser scan line.
Up to 1.27 degrees angle in vertical direction from the scan origin (mirror
motor).
Up to 3.3 mm at 150 mm from the scan origin.
Figure 2: Laser scanning tilt and curvature