Cleaning the Collector Cell

E N G L I S H

Cleaning the Collector Cell

Note: The collector cell may require more frequent cleaning if “arcing” occurs. Arcing is a sharp snapping sound that occurs when large particles of dust are collected in the collector cell. If prolonged or continuous arcing occurs the collector cell should be cleaned.

5

2

3

 

f

r cl

 

 

 

e

 

 

S

o

 

a

 

 

 

 

n

 

P

 

 

 

i

T

I

 

 

 

a

Oreck

 

r

 

 

 

Assail-a-Cell®

cleaner is an excellent way to clean the Collector Cell.

7

1

9

IMPORTANT: Do not try to clean the collector cell by inserting a cloth, brush, or other object between the cell plates.

1Unplug the air purifier.

2Remove the top cover by sliding forward and lifting off.

3Pull the collector cell straight up and out of the cabinet by using the two small handles on each side of the collector cell.

4Place in sink, bathtub or other location where cleaner and contaminants will rinse away without damaging surfaces.

5Spray Oreck Assail-a-Cell®cleaner thoroughly between each cell plate and cover each surface. Allow the cleaner to soak for a few minutes and rinse with clean water. Do not let the cleaner dry on the collector cell.

An alternative method to clean the collector cell is to soak it in warm water for two to three hours. Mild liquid dish detergent may be used to help break down dirt. Rinse thoroughly with clean water.

Note: Do not put in dishwasher or insert objects to clean the collector cell.

Tough residue such as tar from tobacco smoke may need additional applications or longer soaking.

6Allow to dry completely outside of the air purifier. Do not use heated or compressed air to dry. IMPORTANT: Do not reinsert the collector cell until it is completely dry. If the “Check Collector Cell” light blinks red after replacing the collector cell, then the collector cell may still be wet. Remove the collector cell and allow it to finish drying.

7Place the collector cell back into the unit by sliding it straight down into the slots. The collector cell is specially designed so that it can be inserted only in one direction.

8Replace the top cover, sliding back to lock into place. Be sure the top cover and front grill are securely closed or the unit will not operate.

9Reset the “Check Collector Cell” timer by holding down the Air Revitalizer button until the “Check Collector Cell” light blinks three times.