FEATURE OVERVIEW
Switched | Lamp | Lamp and Meter | LED Indicators: | |
Outlets | Receptacle: | Dimmer: | Status indicator lights | |
Pushbutton: | For the | Controls brightness | for Switched Outlets, | |
1 of 2 Triggers that | Convenience Lamp. | of the Ammeter, | DC Voltage Triggers, | |
can activate a turn- | Use to illuminate | Voltmeter | and Unsafe Voltage | |
on or shutdown | working area & | backlighting and |
|
|
sequence for the | other components. | Convenience Lamp. |
|
|
Isolated and High- |
|
|
|
|
Current outlets. |
|
|
|
|
|
|
|
|
|
AC Regeneration
Control and LED
Indicators:
Select either Isolated or Balanced power for your digital source components.
Ammeter:
Backlit analog meter measures current draw for connected equipment up to 15 Amps.
Voltmeter:
Backlit analog meter measures incoming voltage source from
Convenience Outlet: Provides a quick convenient way to plug in components such as camcorders and video game systems.
15A Circuit Breaker: Opens in the event that equipment plugged into the MAX® 5510 draws too much current. When white is visible, the breaker has opened. Reduce the load and push to reset.
Filtered Outlet Bank 1: Two
as
Isolation Transformer Outlets:
Four outlets provide either Isolated or Balanced power for digital source components such as DVD or CD players. Use the front panel AC Regeneration pushbutton to select the desired power mode.
The current available to connected equipment is not limited by the noise filtration components.
AV RCA Jacks: Four pair of RCA style connectors. Circuits are optimized for audio and video signal line protection.
Rear Panel
Convenience Lamp
Receptacle:
Satellite Coax Jacks: Two pair of gold plated
Cable TV Coax Jacks: Gold plated
IEC Main Power | Ground Lug: | Filtered Outlet Bank 2: | Isolation Transformer | Voltage Sense Trigger Inputs: |
|
|
|
| |||||||
Receptacle: | Provides a | Two | Circuit Breaker: | 3.5 mm Mono | |||
Power cord connects | common | Double L filtered outlets | Opens in the event that | trigger device that provides 12VDC to trigger a startup | |||
to this receptacle. | grounding point | for | equipment connected | / shutdown sequence. This is the second trigger that | |||
| for equipment | components such | to the Isolated Outlets | will activate the MAX ® 5510 | |||
| with separate | as | exceeds 4 amps current | sequence. (See switched outlets pushbutton on front | |||
| ground leads | receivers, VCR’s | draw. When white is | panel). | |||
|
| and tape decks. | visible, the breaker has |
|
|
|
|
|
|
| opened. Reduce the |
|
|
|
|
|
|
| load and push to reset. | Isolation Transformer Outlets |
| ||
|
|
|
| ||||
|
|
|
| ||||
|
|
|
| ||||
|
|
|
| Choose between |
Telephone Jacks: | |
| In/Out connections |
for telephone line or | |
Allows adjustment of the | |
protection. | |
| |
Choose between 0, 10 |
|
and 30 seconds. |
|
4 |