Panasonic 1728 manual shall be used

Models: 1728

1 2
Download 2 pages 42.83 Kb
Page 2
Image 2
– 1582 shall be used.)

Type numbers

1728 External Presentation unit (S/W V1.2). 1728SE / 1728UK: Designation texts on the front in Swedish / English. NOTE! In Swedish convention (SBF): "General fault" presentation but no buzzer and no "General disablement" presentation.

1582 External FBP interface board. (Required in EBL512 / 500 when SW mode 1826/28

– 1582 shall be used.)

1587 External FBP / DU interface board. (Required in EBL512 when SW mode 1826/28

– 1587 shall be used. EBL512 software V>2.3.2 1 required.)

4552 RS485 Transceiver component / comm. module. (Required in EBL128. SW mode 1826/28 – 1587 only. EBL128 software V>1.0.5 1 required.)

1Only required if the new functions (buzzer for fault and "General disablement" presentation) shall be used.

NOTE! The number of units that can be power supplied via the c.i.e. / board / external power supply is also depending on all other units connected to the same c.i.e. / board / external power supply.2 Up to 1200 m cable can be used.

The 1728 unit can run in one of two different SW modes:

a)1728 in SW mode 1728 – 1587 has the highest performance with regard to functionality, response time, ability to store fire alarms, etc. In this mode it is intended to succeed the Display unit 2236SE but not as a spare part, since 2236SE is connected to a COM loop and 1728 requires an Ext. FBP / DU interface board 1587 in the EBL512 c.i.e. It is also intended to succeed the Ext. presentation display 2428SE but not as a spare part, since 2428SE requires an Ext. FBP interface board 1582 in the c.i.e. and 1728 requires an Ext. FBP / DU interface board 1587 in the EBL512 c.i.e.

b)1728 in SW mode 1728 – 1582. In this mode it has the same functionality as the ext. Presentation display 2428SE and can be used as a spare part, i.e. the performance is the same but the look, dimensions, etc. are not the same. In this mode 1728 requires an Ext. FBP interface board 1582 in the c.i.e.

Regarding 2236SE / 2428SE: These units have designation texts in Swedish (SE).

 

Technical data

 

 

 

 

Voltage (V DC)

 

 

rated

24

 

allowed

12-30

 

 

 

 

normal (in the system)

24

 

normal (in the system by battery back-up)

21-27

 

 

 

 

Current consumption at norm. volt. (mA)

 

 

quiescent / active

26 (at 24 V), 48 (at 12 V) / 49 (at 24 V), 88 (at 12 V)

 

 

 

Ambient temperature (°C)

 

 

operating

0 to +40

storage

-40 to +70

 

 

 

Ambient humidity (% RH)

max. 90, non condensing

 

 

 

Ingress Protection rating (estimated)

IP61 (with the "O" ring gasket)

 

 

Size W x H x D (mm)

220 x 145 x 50

 

 

 

 

Weight (g)

687

 

 

 

 

Colour (high impact ABS)

Grey (RAL 7035)

 

 

Approvals

CE; Compliant with EN 54-2whenever applicable.

 

 

 

 

2On each 1582 board are up to eight addresses available and on each 1587 board up to sixteen addresses. In EBL128 are up to four addresses available.

All technical features and data are subject to changes without notice, resulting from continuous development and improvement.