Time code (TC) and user’s bit (UB)
16 (E)
When CONV is selected as the TC REGEN setting, the values of the time code which are output to the display panel, remote
controller, SD OUT connector and HD SDI OUT connector may not be the same values in all locations. (See table below)

Time code values which are output for 1 second for each output format

Display panel
00T23
00T23
00T24
00T24
00T29
00T29
00T29
00T29
Remote controller
00T23
00T23
00T24
00T24
00T29
00T29
00T29
00T29
SD OUT connector/525i
00T29
00T29
00T24
00T24
00T29
00T29
00T29
00T29
SD OUT connector/625i HD SDI OUT connector
00T23
00T23
00T24
00T24
00T29
00T29
00T29
00T29
1080/23
Output format
1080/24
1080/25
1080/50
1080/59
1080/60
720/59
720/60
Example: When 1080/23 serves as the format, and the SD OUT connector/525 serves as the output location
The position where the time code value is 00 matches. The time code is displayed in such a way that its value deviates little
by little in the course of one second.
1F 2F 3F 4F 5F
· · · · · · · · · · · · · · · · · ·
· · · · · · · · · · · · · · · · · · · · · 22 23
29F28F27F26F25F 30F
00 01 02 03 04
00 01 02 03 20 21
27 28 2924 25 26
1080/23
SD OUT connector/525i