Chapter 7 Menu description tables

7-2-2 OPTION MODE

Item/

Variable

Remarks

Data storage

range

 

 

 

 

P.OFF GPS DATA

HOLD

For selecting whether or not to hold the UMID

 

CLEAR

GPS position information while the power is

 

 

off and record the information as the data still

 

 

held as the previous value until another

 

 

measurement can be taken after the power is

 

 

next turned on.

 

 

HOLD: The data is held and recorded.

 

 

CLEAR: The data is cleared at the same time

 

 

as the power is turned off, and all

 

 

zeros (no information) are recorded

 

 

from the time the power is turned on

C U F

 

until the measurement is next taken.

 

 

 

COMPONENT OUT

ON

For selecting whether to conserve the power

 

OFF

of the component output to peripheral units.

 

 

ON: Component signals are output to the

 

 

peripheral units.

 

 

OFF: Output stops during power save. (Note

 

 

that this setting is forced ON if a

 

 

camera adapter is connected and a

 

 

tally signal is detected from pin 26.

C U F

 

Otherwise it is OFF.)

 

 

 

1394 SPEED

S100

For setting the transfer speed of the signals to

 

S200

be output from the DVCPRO connector.

 

S400

S100: 100 Mbps

 

 

S200: 200 Mbps

C U F

 

S400: 400 Mbps

 

 

 

1394 IN CH

0

For setting the input channel for the signals to

 

:

be supplied to the DVCPRO connector.

 

63

0-63:

 

AUTO

The channel is fixed at the specified

 

 

number.

 

 

AUTO:

 

 

The channel corresponding to the setting of

C U F

 

the externally connected unit is selected.

 

 

 

1394 OUT CH

0

For setting the output channel for the signals

 

:

to be output from the DVCPRO connector

 

63

0-63:

 

AUTO

The channel is fixed at the specified

 

 

number.

 

 

AUTO:

 

 

The channel corresponding to the setting of

C U F

 

the externally connected unit is selected.

 

 

 

26PIN VIDEO

COMPONENT

For setting the video signals to be output from

SELECT

VIDEO OUT

pin #4 of the 26-pin connector when a 26-pin

 

 

camera adapter is connected.

 

 

COMPONENT:

 

 

The component Y signal is output.

 

 

VIDEO OUT:

 

 

The same signal (composite signal) as the

C U F

 

VIDEO OUT connector signal is output.

 

 

 

Item/

Variable

Remarks

Data storage

range

 

 

 

 

26PIN CONTROL

OFF

For setting whether recording is to be

 

BOTH

controlled by the unit or by both the unit and

 

 

the external VTR which is connected to the

 

 

26-pin camera adapter.

 

 

OFF:

 

 

Recording is performed by the unit only. (It

 

 

is not performed using the external VTR.)

 

 

BOTH:

 

 

Recording is performed by both the unit

 

 

and the external VTR. The tally lamp

 

 

indicates the status of the tally signal of the

 

 

26-pin connector. (The tally lamp setting

 

 

can be established using REC TALLY in

C U F

 

the SYSTEM MODE.)

 

 

 

26PIN CTL

NORMAL

For setting the control signal of the VTR to be

DEFAULT

SPECIAL

output from pin #12 of the 26-pin connector

 

 

when using a VTR connected to a 26-pin

 

 

camera adapter.

 

 

NORMAL:

 

 

STOP “low,” START “high” (for AJ-D92)

 

 

SPECIAL:

C U F

 

STOP “high,” START “low”

 

 

 

The underlining in the variable range column indicates the setting in the preset mode.

82