Check sheet (1/2)
| Check |
| Refer to the following | |
Category | Check item | page and item on | ||
box | Page / Category - | |||
|
| |||
|
|
| Section | |
Safety | □ | Does the vehicle system have a | ||
|
|
|
| |
| □ | Has it been confirmed by testing under actual load, actual circuit, and | ||
| actual condition? |
| ||
| □ | Have load type, load current characteristic, and current value been | ||
| checked? |
| ||
| □ | Isn't the applied contact current too small ? (Small current is likely to | ||
| decrease the contact reliability.) |
| ||
| □ | Has connecting load polarity been checked? | ||
| □ | Is the load likely to cause instant voltage drop? | ||
| □ | Isn't the applied contact voltage too high? (High voltage decreases | ||
| electrical life.) |
| ||
| □ | Isn't applied coil voltage too high? (High voltage affects electrical life.) | ||
| □ | Isn't short pulse applied to coil? | ||
Load/ | □ | Isn't the switching frequency too high even including at abnormality? | ||
|
|
| ||
Electrical life | □ | Doesn't switching continue for a long time? | ||
| □ | Does it switch under high temperature? | ||
| □ | Have precautions been checked for using of coil surge absorption | ||
| circuit? |
| ||
| □ | Have you checked there is no sneak current or voltage to the relay coil? | ||
| □ | Is there stray capacitance between lead wires? | ||
| □ | Have precautions been checked for using of contact protective circuit? | ||
| □ | Is there a risk of dead short in the power supply? | ||
| □ | Is there a risk of short circuit in the power supply at load rejection? | ||
| □ | Is there a risk of insulation and breakdown voltage between contacts in | ||
| each pole when high voltage is applied to a twin relay? |
| ||
| □ | Has hot start been considered? | ||
| □ | Is the ambient temperature within the range of use? Also, is the ambient | ||
| temperature characteristics considered? |
| ||
Coil operation | □ | Is the applied voltage below the maximum continuous applied voltage? | ||
|
|
| ||
voltage | □ | Is there a risk of using PWM control? (PWM control requires careful | ||
| attention.) |
| ||
| □ | Doesn't coil of twin relay operate at the same time? | ||
| □ | Hasn't the current continuously applied to coil over a long period? | ||
|
|
|
| |
| □ | In case of relay operation by electric circuit, is the circuit designed in | ||
Coil operation | consideration of |
| ||
□ | Doesn't the surge voltage of relay cause | |||
circuit | transistor circuit? |
| ||
| □ | When relay is applied to an electric circuit, has voltage drop caused by | ||
| other electric components on the circuit been considered? |
|