Panasonic ASCT1F46E manual Check sheet 1/2, Product name Relay name Date

Models: ASCT1F46E

1 26
Download 26 pages 42.3 Kb
Page 24
Image 24
Product name:

Product name:

Relay name:

Date:

Check sheet (1/2)

 

Check

 

Refer to the following

Category

Check item

page and item on

box

Page / Category -

 

 

 

 

 

Section

Safety

Does the vehicle system have a fail-safe in case of a relay failure?

1/1-1、p1/2-4

 

 

 

 

 

Has it been confirmed by testing under actual load, actual circuit, and

2/4-1

 

actual condition?

 

 

Have load type, load current characteristic, and current value been

2/4-24-9

 

checked?

 

 

Isn't the applied contact current too small ? (Small current is likely to

2/4-10

 

decrease the contact reliability.)

 

 

Has connecting load polarity been checked?

2/4-11

 

Is the load likely to cause instant voltage drop?

2/4-12

 

Isn't the applied contact voltage too high? (High voltage decreases

3/4-13

 

electrical life.)

 

 

Isn't applied coil voltage too high? (High voltage affects electrical life.)

3/4-14

 

Isn't short pulse applied to coil?

3/4-15

Load/

Isn't the switching frequency too high even including at abnormality?

3/4-16

 

 

 

Electrical life

Doesn't switching continue for a long time?

3/4-17

 

Does it switch under high temperature?

3/4-18

 

Have precautions been checked for using of coil surge absorption

3/4-19

 

circuit?

 

 

Have you checked there is no sneak current or voltage to the relay coil?

3/4-20

 

Is there stray capacitance between lead wires?

3/4-21

 

Have precautions been checked for using of contact protective circuit?

4/4-22

 

Is there a risk of dead short in the power supply?

5/4-23

 

Is there a risk of short circuit in the power supply at load rejection?

5/4-23

 

Is there a risk of insulation and breakdown voltage between contacts in

5/4-24

 

each pole when high voltage is applied to a twin relay?

 

 

Has hot start been considered?

5/5-1

 

Is the ambient temperature within the range of use? Also, is the ambient

5/5-2

 

temperature characteristics considered?

 

Coil operation

Is the applied voltage below the maximum continuous applied voltage?

5/5-3

 

 

 

voltage

Is there a risk of using PWM control? (PWM control requires careful

5/5-3

 

attention.)

 

 

Doesn't coil of twin relay operate at the same time?

6/5-4

 

Hasn't the current continuously applied to coil over a long period?

6/5-5

 

 

 

 

 

In case of relay operation by electric circuit, is the circuit designed in

6/6-1、p8/6-2

Coil operation

consideration of mal-function?

 

Doesn't the surge voltage of relay cause mal-function or destruction of

6/6-1、p8/6-2

circuit

transistor circuit?

 

 

When relay is applied to an electric circuit, has voltage drop caused by

6/6-1、p8/6-2

 

other electric components on the circuit been considered?

 

Page 24