WARNING

Be sure to comply with local codes on running the

wire from the indoor unit to the outdoor unit (size

of wire and wiring method, etc.).

Each wire must be firmly connected.
No wire should be allowed to touch refrigerant

tubing, the compressor, or any moving part.

Be sure to connect power wires correctly match-

ing up numbers on terminals of the outdoor unit

and respective indoor units A – D.

CAUTION
Be sure to connect the power supply line to the

outdoor unit as shown in the wiring diagram. The

indoor unit draws its power from the outdoor unit.

Do not run wiring for antenna, signal, or power

lines of television, radio, stereo, telephone, secu-

rity system, or intercom any closer than 3'4" (1 m)

from the power cable and wires between the

indoor and outdoor units. Electrical noise may

affect the operation.

To avoid the risk of electric shock, each air conditioner

unit must be grounded.

For the installation of a grounding device, please

observe local electrical codes.

Grounding is necessary, especially for units using

inverter circuits, in order to release charged electricity

and electrical noise caused by high tension.

Otherwise, electrical shock may occur.

Place a dedicated ground more than 7' (2 m) away from

other grounds and do not have it shared with other

electric appliances.

WARNING

Fig. 25a

Fig. 25b

4 indoor units with CU-4KS24NBU, CU-4KS31NBU

1
2
3
Terminal
INDOOR UNIT
1
2
3
INDOOR UNIT
1
2
3
1
UNIT B
2
3
4
UNIT C
5
6
7
8
9
1
2
TerminalTerminal
L1
L2
INDOOR UNIT
UNIT A
(A)
(B)
(C)
Terminal
(2P)
Terminal(9P)
OUTDOOR UNIT
Disconnect
switch
*
*
*
230/208V
230/208V
230/208V
230/208V
230/208V
230/208V
230/208V
230/208V
230/208V
Grounding
line
Grounding
line
Disconnect
switch Field supply
Disconnect
switch Field supply
Field supply
Power supply
Single-phase 230/208VAC 60HZ
Grounding
line
Grounding line
(A)
(B)
(B)
(B)
(B)
(B)
(B)
(C)
(C)
(C)
1
2
3
Terminal
1
UNIT B
2
3
4
UNIT C
5
6
7
UNIT D
8
9
10
11
12
1
2
L1
L2
INDOOR UNIT
UNIT A
(A)
1
2
3
Terminal
INDOOR UNIT
(B)
Terminal
(2P)
Terminal(12P)
OUTDOOR UNIT
Disconnect
switch
230/208V
230/208V
230/208V
230/208V
230/208V
230/208V
Grounding line
Grounding line
Field supply
230/208V
230/208V
230/208V
230/208V
1
2
3
Terminal
INDOOR UNIT
(C)
1
2
3
Terminal
INDOOR UNIT
(D)
(Inter-unit)
power line
230/208V
230/208V
Power supply
Single-phase 230/208VAC 60HZ
Grounding line
Grounding
line
Grounding
line
Disconnect switch
Field supply
Disconnect
switch
Field supply
Disconnect switch
Field supply
(A)
(B)
(B)
(B)
(B)
(B)
(B)
(B)
(B)
(C)
(C)
(C)
(C)
*
*
*
*

3 indoor units with CU-3KS19NBU

5-3. Wiring System Diagram

*

Disconnect switch may be required by

national or local codes.

Always comply with national and local code

requirements.

CAUTION

NOTE