< Low Ambient Cooling Operation >

When the mode is switched from cooling opration to low ambient cooling operation,
the compressor is stopped for 150 seconds temporarily.
Outdoor fan speed [ rpm ]
Outdoor air temperature
32 °F ( °C )
When the mode has been switched to low ambient cooling operation,
the outdoor fan speed is lowered as the outdoor air temperature falls.
When the outdoor air temperature reaches 57.2 °F (14 °C ) or less during the cooling operation,
the operation mode is switched to low ambient cooling operation.
The following protective actions are available to prevent the compressor from operating
with abnormal loads.
At that time, they initiate thermo-off ( stopping the outdoor unit ) of the air conditioner.
When the outdoor air temperature reaches 62.6 °F (17 °C ) or more during the low ambient
cooling operation, the operation mode is switched to cooling operation.
8.6 (-13)
14 (-10)
Compressor
Indoor fan
OFF
ON ON
Outdoor air temp.
°F ( °C )
ON
68