25
123
123
123
123

Indoor unit B

Indoor unit A

Ground
Power:
Single-phase,
230/208VAC 60HZ
Power breaker
(not provided)

Outdoor unit

Terminal board
Label A
Inter-unit cables
#14 (not provided)
Terminal board
Inter-unit cables
#14 (not provided)
Terminal board Label B Label C
Inter-unit cables
#14 (not provided)
Inter-unit cables
#14 (not provided)
Terminal board
Terminal board
Label D
A
BC
D
Power cable (not provided)
(#12: Less than 85 ft.)

Be sure to perform grounding.

Attach a ground wire to either the

outdoor unit or indoor unit.

If there is a grounding terminal

inside the room, use the grounding

screw inside the indoor unit.

Be sure to apply the provided labels to both

ends of the inter-unit cables to prevent mis-

wiring. The units will not function if the wiring

connections are incorrect.

A is the indoor unit with
refrigerant tubing that is
connected to service valve
A (bottom) of the outdoor unit.
refrigerant tubing that is
connected to service valve B
(second from the bottom) of
the outdoor unit.
B is the indoor unit with

Indoor unit C

refrigerant tubing that is
connected to service valve
C (third from the bottom)
of the outdoor unit.
C is the indoor unit with

Indoor unit D

refrigerant tubing that is
connected to service valve
D (top) of the outdoor unit.
D is the indoor unit with
1 2
1 2 3 4 5 6 7 8 9 10 11 12 Power supply
(conduit)
Inter Unit
(conduit)
Inter Unit
(conduit)
# ... AWG (American Wire Gauge)

5-5. Wiring Instructions for the Outdoor Unit

Be sure to correctly align inter-unit cables A, B, C and D.
Use a dedicated air conditioner circuit for power.
To make connections to the outdoor unit, remove the inspection panel and tubing panel.
Do not bring the inter-unit cables or power cable into contact with tubing or service valves.
Use outdoor unit cable fasteners and fasten the inter-unit cables at the location where the cables are double-

sheathed.

Arrange the wiring so that the inter-unit cables are contained in the inspection panel and tubing panel, as shown in

Fig. 31.

CAUTION

Fig. 31