Setting the Fan Speed
Press 4 to select:-
FAN Low Fan Speed
FAN Medium Fan Speed
FAN High Fan Speed
AUTO
FAN Automatic Fan Speed
The speed of the indoor fan is adjusted
automatically according to the operation.
The indoor fan stops occasionally during
cooling operation.
Vertical Airflow Direction
Manual Operation
Press and hold the Manual Airflow Direction
Selection Button 5 , then release the button at
the desired airflow direction.
Cooling / Soft Dry/
Heating (for Heat-Pump Model only)
The airflow direction can be adjusted as desired
by using the remote control. This is effective
when you want to cool yourself directly, such as
when coming out of the bath. The louver can be
adjusted within a range between the horizontal
and 25 degrees downward at Cooling and Soft
Dry Operation, and between the horizontal and
45 degrees downward at Heating Operation.
(for Heat-Pump Model only)
Setting the Horizontal Airflow Direction
Use this air conditioner under the following
conditions:
Cooling Model
Adjust it manually
Notes
If the unit is not going to be used for an extended
period of time, turn off the main power supply. If it is
left at the ON position, approximately 2.0 W of
electricity will be used even if the indoor unit has been
turned off with the remote control.
If operation is stopped, then restart immediately, the
unit will resume operation only after 3 minutes.
DBT: Dry Bulb Temp
WBT: Wet Bulb Temp
Maximum Temperature-Cooling
(Maximum Temperature-Heating)
Minimum Temperature-Cooling
(Minimum Temperature-Heating)
DBT
32
(30)
16
(16)
WBT
23
(-)
11
(-)
DBT
43
(24)
16
(-5)
WBT
26
(18)
11
(-6)
Indoor
Outdoor
(Unit in °C)
Heat Pump Model
DBT: Dry Bulb Temp
WBT: Wet Bulb Temp
Maximum Temperature
Minimum Temperature
DBT
32
16
WBT
23
11
DBT
43
16
WBT
26
11
Indoor Outdoor
(Unit in °C)
Downward
Horizontal
Automatic Operation
Press the Auto Airflow Direction Button 6.
Cooling / Soft Dry
The louver will automatically swing up and down
to create the feeling of a refreshing breeze.
Heating (for Heat-Pump Model only)
When the discharge air temperature is low such
as at starts of heating operation, the air blows at
horizontal level.
As the temperature rises, the hot air blows in a
downwards direction.
OFF/ON
TEMP
MODEFAN SPEED
AUTO
TIMER
AIR SWING
RESET
AUTO
COOL
FAN
FAN
SPEED
DRY
C
HH
OFF ONOFFON
SLEEP
3
2
1
4
5
SELECTSET/CANCEL
AB
CONVENIENCE OPERATION
Sleep Mode Operation
To obtain a comfortable room temperature while sleeping:-
Press 5.
Sleep mode indicator on the indoor unit will light up.
To cancel this operation, press once more.
Sleep Mode Operation Details
When the room temperature reaches the set temperature,
the airflow volume will change to low automatically.
Sleep Mode Operation time is 8 hours.
When used together with the timer, the timer has a priority.
Cooling Model
CARE AND MAINTENANCE

Cleaning the Indoor Unit and Remote

Control

Wipe gently with a soft, dry cloth.
Do not use water hotter than 40˚C or polishing fluid
to clean the unit.

Cleaning the Air Filter

(Recommendation:- If the unit is operated in a dusty
environment, clean the filters every two weeks,
continuous use of this dirty filters will reduce cooling
or heating efficiency)
1
Remove dirt using a vacuum cleaner.
2
Wash back of the air filter with water.
3
If badly soiled, wash it with soap or a mild household
detergent.
4
Let it dry and reinstall it.
Be sure the FRONT mark is facing you.
*Damaged air filter.
Consult the nearest authorized dealer.
Part No.: CWD001088.
Do not use benzene, thinner, scouring powder or
clothes soaked in caustic chemical to clean the
unit.
H
OFF
H
ON
H
ON
H
OFF
H
ON
H
OFF
SETTING THE TIMER
Press the Timer Selection Button 1.
Timer indicator on the indoor unit will light up.
Select one of the following five types of operation.
Each time the button is pressed, the operation mode
is shifted in the arrow direction.
Delay OFF Timer Example :
Operation Stops
after 1 hour
ON Timer.
Delay ON Timer Example :
Operation starts after
6 hours.
Delay OFF and Example :
ON Timer Operation stops after
1 hour and re-starts
after another 5 hours.
Delay ON and Example :
OFF Timer Operation starts after
10 hours, and then
stops after another 8
hours.
Then press the Timer Setting Button 2 or 3 to the
desired number of hours.
(Number of hours which can be set : 1 ~ 12)
Press the Timer Set/Cancel Button 4.
Heat Pump Model
1 hour
Sleep shift
operation starts.
Approx. 3°C
decrease.
Cooling or Soft Dry
Operation for sleep shift
operation will start to
avoid overcooling.
Heating operation for
sleep shift operation will
start to avoid overheating.
Sleep
Operation
button is
pressed.
0~1 hour
Approx. 2°C
decrease.
Approx.
0.5°C
increase.
Approx. 0.5°C
increase.
Temperature
S
e
t
t
i
n
g
T
e
m
p
e
r
a
t
u
r
e
Time
1 hour
after approx. 8 hours of sleep shift
operation, it will stop automatically.
Time
Approx. 0.5°C
increase.
Temperature
Sleep
Operation
button is
pressed.
Sleep shift
operation
starts.
0~1 hour 1 hour
after approx. 8 hours of sleep shift
operation, it will stop automatically.
Approx.
0.5°C
increase. Cooling or Soft Dry
Operation for sleep shift
operation will start to
avoid overcooling.
S
e
t
t
i
n
g
T
e
m
p
e
r
a
t
u
r
e
37

CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 /CS-A24CTP CU-A24CTP5