CARE & CLEANING
CAUTION
•Switch off the power supply before cleaning.
•Do not touch the aluminium fin, sharp parts may cause injury.
WASHING INSTRUCTIONS
•Do not use benzene, thinner or scouring powder.
•Use only soap ( pH7) or neutral household detergent.
•Do not use water hotter than 40°C.
HINT
•To ensure optimal performance of the unit, cleaning maintenance have to be carried out at regular intervals. Dirty unit may caused malfunction and you may retrieve error code “H99”. Please consult authorized dealer.
ALUMINIUM FIN
Remove
e-ion FILTERS
•Clean the filters regularly.
•Wash/rinse the filters gently with water to avoid damage to the filter surface.
•Dry the filters thoroughly under the shade, away from fire or direct sunlight.
•Replace any damage filter.
FRONT PANEL
Remove Front Panel
• Raise and pull to remove the front panel.
• Wash gently and dry.
Close Front Panel
• Press down both ends of the front panel to close it securely.
INDOOR UNIT
Wipe the unit gently with a soft, dry cloth.
ACTIVE
Clean with dry cotton bud.
• Active
6
FOR SEASONAL INSPECTION AFTER EXTENDED NON-USE
•Checking of remote control batteries.
•No obstruction at air inlet and air outlet vents.
•Use Auto OFF/ON button to select Cooling/Heating operation, after 15 minutes of operation, it is normal to have the following temperature difference between air inlet and air outlet vents:
Cooling: ≥ 8°C | Heating: ≥ 14°C |
FOR EXTENDED NON-USE
•Activate Heat mode for 2~3 hours to remove moisture left in the internal parts thoroughly to prevent mould growth.
•Turn off the power supply.
•Remove the remote control batteries.
NON SERVICEABLE CRITERIAS
TURN OFF POWER SUPPLY then please consult authorized dealer under the following conditions:
•Abnormal noise during operation.
•Water/foreign particles have entered the remote control.
•Water leaks from Indoor unit.
•Circuit breaker switches off frequently.
•Power cord becomes unnaturally warm.
•Switches or buttons are not functioning properly.