Aluminum Electrolytic Capacitor

■ Typical failure modes and their factors

 

 

 

 

 

 

Faliure mode

Faliure mechanism (internal phenomenon)

Production factor

Application factor

 

 

 

 

 

 

 

 

 

 

Overvoltage applied

Vent operates

 

Increase in

•

Increase in inter-

•

 

 

 

 

internal pressure

 

nal temperature

 

 

 

 

 

 

 

 

 

 

 

 

•

Excessive ripple current

Capacitance

 

Reduced anode foil

 

 

 

 

 

 

 

 

 

 

 

 

 

 

reduction

 

capacitance

 

 

 

 

 

 

 

Reverse voltage applied

 

 

 

 

 

 

 

 

•

 

 

 

 

 

 

 

 

 

•

 

•

 

•

•

 

 

•

 

 

tan d increase

 

Reduced cathode

 

 

 

 

 

 

 

 

foil capacitance

 

 

 

 

 

•

Severe charging-discharging

 

 

 

 

 

 

 

 

 

 

AC voltage applied

 

 

 

 

 

 

 

 

•

Defect of oxide film

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

•

•

Used for a high temperature

 

 

Deterioration of

 

•

 

 

•

Insufficient

 

 

 

oxide film

 

 

 

 

 

electrolyte

 

 

 

 

 

 

 

 

 

 

Leakage current

•

•

 

 

 

 

 

 

 

Used for a long period of time

increase

 

 

 

 

 

 

 

 

 

 

Electrolyte evapora-

 

 

 

 

 

 

 

 

 

 

•

 

Metal particles

 

 

 

tion

 

 

 

 

 

 

 

 

 

 

 

 

 

in capacitor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

•

•

 

Stress applied to leads

Short circuit

 

Insulation breakdown of film

•

 

 

 

 

 

or electrolytic paper

 

 

 

Burr(s) on foil leads

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Leads improperly

 

 

 

 

 

 

 

 

 

 

connected

 

 

 

Leads improperly connected

 

•

 

Mechanical stress

 

Open

•

•

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Use of Halogenated solvent

 

 

Corrosion

 

Infiltration of Cl

 

 

•

 

 

 

 

 

 

 

 

 

 

 

Use of adhesive

 

 

 

 

 

 

 

 

 

 

Use of coating material