Installation II (In remodeling)
NOTE:
If the wall thickness is more than 152.4 mm (6"), refer to the reference installation drawing when the wall thickness is more than 152.4 mm (6") on page 2.
1.Cut holes in the interior and exterior walls. (Fig. 10)Cut a hole in the interior wall using the attached template (pattern paper), and make a 215 mm (8 1/2”) hole in the exterior wall.
CAUTION:
The hole should be made in an area where pipes, cables and telephone lines are not run, and there are no studs in the way.
2.Lay interior wiring through the wall using a flexible con- duit.3.Remove the junction box from the wall sleeve by remov- ing two screws (C). (Fig. 11)
4.Remove the junction box cover by removing screw (B).
5.Remove the screws (D) and replace the wall sleeve flange with the mounting flange. (The mounting plate face should align with the end of the wall sleeve which is protruding from indoor side.)
6.Attach the wall sleeve to the wall with supplied screws (Screw I). (Fig. 12)If the interior wall material is plaster board, use appropri- ate fasteners (locally available) to secure the wall sleeve.
Hole in the
exterior wall
Hole in the interior wall
Fig. 10
Mounting plate
|
| Flange |
| Junction box | Wall sleeve |
|
| |
B |
| D |
| C | |
|
|
Fig. 11
A hole where the junction box was attached to the wall sleeve.
Fasterners,
etc.
Mounting plate
Fig. 12
7