5.Remove the lighting cord out from hook
6.Refer to wiring diagram (Page.5)
Follow all the local electrical safety codes. As well as the National Electrical Code (NEC).
Using UL approved wire nuts, connect house power wires to ventilating fan wires (Fig.6):
Black to black; white to white; green to green. Make sure all connections are fastened firmly after wiring is finished.
Replace the junction box plate, and then replace lighting cord to hook. (Fig.5)
Lighting cord | Screw driver | |
| Junction box | |
| plate | |
Hook | Screw | |
Fig.5 | ||
| ||
Black to black | White to white | |
Junction box plate White to white | Black to black | |
| Green to green | |
| Wire nut | |
Black to black | Black to black | |
| ||
White to white | Junction box | |
| ||
| Conduit | |
| Fig.6 | |
Conduit | Circular duct | |
Fan body | Duct tape | |
or clamps | ||
Joist | ||
|
7.Install the circular duct (4 inches) to the adaptor and secure it with duct tape or clamps. (Fig.7)
8.Finish ceiling work. Ceiling hole should be aligned with the edge of the flange. (Fig.8)
9. Install the fluorescent lamps and then install the night lamp. (Fig.8)
10.Insert mounting springs into slots as shown and mount grille to fan body. (Fig.9)
Note:Do not mount grille and springs conversely. If the grille is mounted in the opposite direction, the grille can not be fitted to the ceiling, so then reverse the grille position and try to mount again.
4 Long screws (ST4.2X20) |
|
|
|
|
|
| Fig.7 | |
|
|
|
|
|
|
| ||
| 17 3/8 (441) |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 19 | ) |
|
|
|
|
| ( | 3 |
| |
|
|
|
| /8 |
|
| ||
|
|
|
|
|
|
| ||
Night lamp |
| 2 | 5 |
|
|
|
| |
1 |
|
|
|
|
| |||
|
|
|
|
|
| |||
|
|
|
|
|
|
| Fig.8 | |
| Fluorescent lamp |
| ||||||
Slot | Mounting spring |
|
|
|
|
|
|
|
Correct |
|
|
|
|
|
|
|
|
Incorrect |
|
|
|
|
|
|
|
|
| Grille |
|
|
|
|
|
| Fig.9 |
| Switch |
|
|
|
|
|
| Switch |
| labels |
|
|
|
|
|
| labels |
(Fig.10) | Fig.10 |
For Model | For Model |