LAMP indicator

 

 

 

Indicator

Illuminated (red)

Flashing (red)

display

 

 

 

 

 

 

It is nearly time to

An abnormality has been detected in the lamp

Problem replace the lamp

circuit.

Cleaning and replacing the air filter

If the air filter becomes clogged with dust, the internal temperature of the projector will rise, the TEMP indicator will flash and the projector power will turn off. The air filter should be cleaned every 100 hours of use, depending on the location where the projector is being used.

 

unit.

 

 

 

 

 

 

 

B Does “REPLACE

B The power may

B There may be an

Possible

LAMP” appear on

have been turned

abnormality in the

the screen after

on straight away

lamp circuit.

cause

the projector is

after it was turned

 

 

 

 

turned on?

off.

 

 

 

 

 

 

B This occurs when

B Wait for a while

B Turn off the MAIN

 

the operation time

until the lamp unit

POWER switch by

 

for the lamp unit is

cools down before

following the

 

nearing 1800

turning the power

procedure given

 

hours. (when

back on again.

on page 23, and

 

LAMP POWER

 

then contact an

Remedy

has been set to

 

Authorised

“HIGH”) Ask your

 

Service Centre.

 

 

 

dealer or an

 

 

 

Authorised

 

 

 

Service Centre to

 

 

 

replace the lamp

 

 

 

unit.

 

 

 

 

 

 

NOTE:

 

 

 

BBe sure to turn off the MAIN POWER switch by following the procedure given in “Turning off the power” on page 23 before carrying out any of the procedures in the “Remedy” column.

BIf the main power turns off after the TEMP indicator starts flashing, it means that an abnormality has occurred. Please contact an Authorised Service Centre so that the necessary repairs can be made.

Cleaning procedure

#Turn off the MAIN POWER switch and disconnect the power cord plug from the wall outlet.

Turn off the MAIN POWER switch according to the procedure given in “Turning off the power” on page 23 before disconnecting the plug from the wall outlet.

$Gently turn the projector upside down.

NOTE:

BPlace the projector on top of a soft cloth so that it will not become scratched.

%Remove the air filter.

Put your fingernails under the air filter and pull the air filter out of the projector.

&Clean the air filter.

Use a vacuum cleaner to clean off any accumulated dust.

NOTE:

BBe careful not to let the air filter get sucked into the vacuum cleaner.

'Install the air filter.

NOTE:

BBe sure to install the air filter cover before using the projector. If the projector is used without the air filter cover installed, dust and other foreign particles will be drawn into the projector, and malfunctions will result.

BIf the dust cannot be removed by cleaning, it is time to replace the air filter. Please consult your dealer. Furthermore, if the lamp unit is being replaced, replace the air filter at this time also.

Others

Air filter

40-ENGLISH

ENGLISH-41

Page 21
Image 21
Panasonic PT-AE100E manual Cleaning and replacing the air filter, Cleaning procedure