Care and maintenance
ENGLISH-4948-ENGLISHLamp unit replacement procedure
#Turn off the MAIN POWER
switch according to the
procedure given in “Turning off
the power” on page 24, and
then disconnect the power
cord plug from the wall outlet
and check that the area around
the lamp unit has cooled down.
$Use a Phillips screwdriver to
turn the lamp unit cover fixing
screws at the bottom of the
projector, and then remove the
lamp unit cover from the
projector.
%Use a Phillips screwdriver to
loosen the two lamp unit fixing
screws until the screws turn
freely. Then hold the handle of
the lamp unit and gently pull it
out from the projector.
&Insert the new lamp unit while
making sure that the direction
of insertion is correct, and then
use a Phillips screwdriver to
securely tighten the lamp unit
fixing screws.
Lamp indicator warning
light
On-screen display
Illuminates red during
image projection and
standby mode.
Displayed for 30
seconds. Pressing any
button will clear the
display.
More than 1 800 hours
Remains displayed until
any button is pressed.
More than 2 000 hours
NOTE:
BIf the lamp usage time has passed 2 000 hours (when “LAMP POWER”
has been set to “HIGH”), the projector will switch to standby mode after
approximately 10 minutes of operation. The steps )to ,on the next
page should thus be completed within 10 minutes.
Lamp unit cover
Lamp unit cover fixing screws
Handle
Lamp unit fixing screws