Transmission from the computer

(Used Only for PT-D10000/DW10000)

Transmission from the computer begins with STX, then the ID, command, and ETX are sent in this order.

When self-diagnosis result operation in the PT-D10000/DW10000, read commands of C1 and C2 command is necessary.

A command is binary 4 byte command.

STX
Start
0x02
ID
ID
0x00 ~ 0x40
C1
Command
0xfe
C2
Command
0xfe
ETX
End
0x03

ID:

ID ALL=0x00, ID1=0x01, ID2=0x02, ID3=0x03, ID4=0x04, ... ,ID63=0x3f, ID64=0x40
Projector default setting is ID ALL.
Responses from the projector

(Used Only for PT-D10000/DW10000)

STX
Start
0x02
ID
ID
0x00 ~ 0x40
C1
Command
0xfe
bit127
P1 P2 P3 P14 P15 P16C2
Command
0xfe
ETX
End
0x03

Responses are binary 21 byte command.

Self-diagnosis results are 16 byte (128bit) command.

bit0
Self-diagnosis information 16 bytes
(128 bits)
9