2.30. Query Contrast

Hexadecimal

02h

51h

56h

52h

03h

Character

 

Q

V

R

 

„Response (Callback)

In the period when the command can be accepted

 

 

 

 

 

Hexadecimal

02h

*1

*3

 

*5

03h

 

 

 

 

Character

 

 

*2

*4

 

*6

 

 

 

 

 

Acceptability

 

 

 

 

 

 

 

 

 

 

 

 

SECURITY

STANDBY

 

NO SIGNAL

 

SHUTTER

REMOTE

 

 

Yes

 

No

 

No

 

 

 

Yes

Yes

 

„Parameters (*1, *2, *3, *4, *5, *6)

Hexadecimal

2Dh

−32

32h

2Dh

−31

31h

2Dh

−30

30h

33h

33h

33h

Character

3

2

3

1

3

0

Hexadecimal

30h

30

30h

30h

31

31h

30h

32

32h

33h

33h

33h

Character

0

3

0

0

3

1

0

3

2

2.31. Query Sharpness

Hexadecimal

02h

51h

56h

53h

03h

Character

 

Q

V

S

 

„Response (Callback)

In the period when the command can be accepted

 

 

 

 

 

Hexadecimal

02h

*1

*3

 

*5

03h

 

 

 

 

Character

 

 

*2

*4

 

*6

 

 

 

 

 

Acceptability

 

 

 

 

 

 

 

 

 

 

 

 

SECURITY

STANDBY

 

NO SIGNAL

 

SHUTTER

REMOTE

 

 

Yes

 

No

 

No

 

 

 

Yes

Yes

 

„Parameters (*1, *2, *3, *4, *5, *6)

Hexadecimal

2Dh

−08

38h

2Dh

−07

37h

2Dh

−06

36h

30h

30h

30h

Character

0

8

0

7

0

6

Hexadecimal

30h

13

33h

30h

14

34h

30h

015

35h

31h

31h

31h

Character

0

1

3

0

1

4

0

1

5

2.32. Query White Balance - R

Hexadecimal

02h

51h

57h

52h

03h

Character

 

Q

W

R

 

„Response (Callback)

In the period when the command can be accepted

 

 

 

 

 

Hexadecimal

02h

*1

*3

 

*5

03h

 

 

 

 

Character

 

 

*2

*4

 

*6

 

 

 

 

 

Acceptability

 

 

 

 

 

 

 

 

 

 

 

 

SECURITY

STANDBY

 

NO SIGNAL

 

SHUTTER

REMOTE

 

 

Yes

 

No

 

No

 

 

 

Yes

Yes

 

„Parameters (*1, *2, *3, *4, *5, *6)

Hexadecimal

2Dh

-32

32h

2Dh

-31

31h

2Dh

-30

30h

33h

33h

33h

Character

3

2

3

1

3

0

Hexadecimal

30h

30

30h

30h

31

31h

30h

32

32h

33h

33h

33h

Character

0

3

0

0

3

1

0

3

2

2.33. Query White Balance - G

Hexadecimal

02h

51h

57h

47h

03h

Character

 

Q

W

G

 

„Response (Callback)

In the period when the command can be accepted

 

 

 

 

 

Hexadecimal

02h

*1

*3

 

*5

03h

 

 

 

 

Character

 

 

*2

*4

 

*6

 

 

 

 

 

Acceptability

 

 

 

 

 

 

 

 

 

 

 

 

SECURITY

STANDBY

 

NO SIGNAL

 

SHUTTER

REMOTE

 

 

Yes

 

No

 

No

 

 

 

Yes

Yes

 

„Parameters (*1, *2, *3, *4, *5, *6)

Hexadecimal

2Dh

−32

32h

2Dh

−31

31h

2Dh

−30

30h

33h

33h

33h

Character

3

2

3

1

3

0

Hexadecimal

30h

30

30h

30h

31

31h

30h

32

32h

33h

33h

33h

Character

0

3

0

0

3

1

0

3

2

10/16

Page 10
Image 10
Panasonic PT-F100 specifications 10/16