8/16 2.24. Query Lamp Status 2.25. Query Input Change
Character Q P W
Response (Callback) OFF
Hexadecimal 02h 30h 30h 31h 03h
Character 0 0 0
ON
Hexadecimal 02h 30h 30h 31h 03h
Character 0 0 1
Acceptability
SECURITY STANDBY NO SIGNAL
SHUTTER
REMOTE
Yes Yes Yes Yes Yes
Hexadecimal 02h 51h 24h 53h
03h
Character Q $ S
Response (Callback) Lamp OFF
Hexadecimal 02h 30h 03h
Character 0
In turning ON
Hexadecimal 02h 31h 03h
Character 1
Lamp ON
Hexadecimal 02h 32h 03h
Character 2
In turning OFF
Hexadecimal 02h 33h 03h
Character 3
Acceptability
SECURITY STANDBY NO SIGNAL
SHUTTER
REMOTE
Yes Yes Yes Yes Yes
Hexadecimal 02h 51h 49h 4Eh
03h
Character Q I N
Response (Callback) COMPUTER 1
Hexadecimal 02h 52h 47h 31h 03h
Character R G 1
COMPUTER 2
Hexadecimal 02h 52h 47h 32h 03h
Character R G 2
VIDEO
Hexadecimal 02h 56h 49h 44h 03h
Character V I D
S-VIDEO
Hexadecimal 02h 53h 56h 44h 03h
Character S V D
COMPONENT
Hexadecimal 02h 59h 55h 56h 03h
Character Y U V
NETWORK
Hexadecimal 02h 4Eh 57h 50h 03h
Character N W P
Acceptability
SECURITY STANDBY NO SIGNAL
SHUTTER
REMOTE
Yes No Yes Yes Yes