ENGLISH - 41
Maintenance
LAMP and TEMP Indicators
If a problem should occur with the projector, the LAMP and/or TEMP indicators
will inform you. Manage the indicated problems as follow.
1. Confirm the status of all indicators and projector, and switch off the
projector in proper way.
See “Switching the projector on/off” on page 20.
2. Find out the cause of the problem by status of the LAMP and/or TEMP
indicators.
3. Follow the instruction for each indication below and solve the problem.
4. Turn on the projector in the correct way and confirm the indicator is not
indicating a problem any longer.

JLAMP indicator

JTEMP indicator

Managing the indicated problems

NOTE:
If no problem is found or the problem remains, do not turn on the projector. Instead contact an Authorised Service Centre.
Indicator Illuminating red Flashing red
Problem LAMP RUNTIME has
reached 2 800 hours. LAMP circuit failure, abnormal function or the lamp unit is damaged.
Cause
Lamp unit will run out
soon and needs to be
replaced.
The projector is switched
on again too soon.
LAMP circuit failure,
abnormal function. Lamp unit is damaged.
Remedy See “Replacing the Lamp
unit” on page 43.
Let the lamp unit cool
down and turn on the
projector after
90 seconds.
Switch off the projector
and contact an Authorised
Service Centre.
See “Replacing the Lamp
unit” on page 43.
Indicator Illuminating red while projecting and the alert will be displayed.
Flashing red and power is turned off
Problem The temperature inside and/or outside the projector is abnormally high.
Cause The ventilation openings
are covered.
The room temperature is
too high.
The filter is excessively
dirty and the ventilation is
poor.
The projector is located at
1 400 - 2 700 m (4 593 -
8858 ft).
Remedy
Remove the object(s)
from the ventilation
openings or clear around
the projector.
Reinstall the projector in
temperature controlled
place. See page 50.
Clean the filter in the
proper method. See
page 42.
Turn on the projector*1
and set the ALTITUDE to
HIGH. See page 37.
*1. The projector will perform 2 minutes with LO W setting at high elevation.
LAMP TEMP