Care and Replacement

ENGLISH - 43
Maintenance
The lamp unit, ET-LAB80 is consumable and you must replace it regularly. It is recommended that a qualified
technician carry the lamp unit replacement and consult with an Authorised Service Centre.

JWhen to replace the Lamp unit

When the lamp is consumed, the brightness may decrease over time. 3 000 hours of use is the replacing
timing as rough guided, and that might be shortened by the usage conditions, characteristics of the lamp unit
or environmental conditions. You can find the duration of usage time by checking LAMP RUNTIME in OPTION
menu.

JBefore replacing the lamp unit

Contact an Authorised Service Centre to purchase a replacement lamp unit (ET-LAB80).
Switch off the projector and disconnect the mains plug from the mains socket.
Wait for more than 1 hour and make sure the lamp unit and the surroundings are cooled enough.
Prepare a Phillips-head screwdriver.
When the projector is mounted in the ceiling, do not work directly under the projector or put your face closer
to the projector.
Replacing the Lamp unit
Indication
On screen LAMP indicator
Over 2 800 hours Displays “REPLACE LAMP” on the upper
left of the screen for 30 seconds.
Illuminates red.
Over 3 000 hours
Displays “REPLACE LAMP” on the upper
left of the screen, and it will stay until you
respond. Press any button to clear the
screen.
NOTE:
The guide times, 2 800 and 3 000 hours, are rough estimates based on certain conditions and is not a guaranteed time.
For more information about the lamp unit and its guaranteed time, see the instructions which is provided with the lamp
unit.
Do not use a lamp unit over 3 000 hours. Failure to observe this may result in explosion of the lamp.
NOTE:
Prior to replacing the lamp unit, allow it to cool down to prevent the risk of burns, damage and other hazards.
Do not attempt replacement with an unauthorised lamp unit.

REPLACE LAMP