How to connect the SERIAL Terminals

Connections

How to connect the SERIAL Terminals

The SERIAL terminal is used when the Plasma Display is controlled by a computer.

COMPUTER

SERIAL

Ferrite core

RS-232C

(supplied)

straight cable

D-sub 9p

Less than

 

7" 7/8 (20 cm)

Notes:

(1)Use the RS-232C cable to connect the computer to the Plasma Display.

(2)The computers shown is for example purposes only.

(3)Additional equipment and cables shown are not supplied with this set.

6 7 8 9

1 2 3 4 5

Pin layout for RS-232C

The SERIAL terminal conforms to the RS-232C interface specification, so that the Plasma Display can be controlled by a computer which is connected to this terminal.

The computer will require software which allows the sending and receiving of control data which satisfies the conditions given below. Use a computer application such as a programming language to software. Refer to the documentation for the computer application for details.

Communication parameters

Signal level

RS-232C compliant

 

 

Synchronization method

Asynchronous

Baud rate

9600 bps

 

 

Parity

None

 

 

Character length

8 bits

Stop bit

1 bit

 

 

Flow control

-

 

 

 

RS-232C Conversion cable

D-sub 9-pin female

Details

2

 

R X D

3

 

T X D

5

 

GND

4

6

Non use

7

 

Shorted

8

 

 

 

1 •

9

NC

Basic format for control data

The transmission of control data from the computer starts with a STX signal, followed by the command, the parameters, and lastly an ETX signal in that order. If there are no parameters, then the parameter signal does not need to be sent.

STX Communication parametersBasic format for control data C1 C2 C3 CommandManual background : Manual backgroundManual background P1 P2 P3 P4 P5 Manual backgroundManual background ETX

 

 

 

 

Colon

 

Parameter(s)

 

End

 

 

 

 

 

 

Start

 

3-character

(1 - 5 bytes)

 

(03h)

 

 

(02h)

 

command (3bytes)

 

 

 

Notes:

(1)If multiple commands are transmitted, be sure to wait for the response for the first command to come from this unit before sending the next command.

(2)If an incorrect command is sent by mistake, this unit will send an “ER401” command back to the computer.

Command

Command

Parameter

Control details

PON

None

Power ON

POF

None

Power OFF

AVL

**

Volume 00 - 63

 

Audio mute OFF

AMT

0

1

Audio mute ON

 

IIS

None

Input select (toggle)

 

VID

AV Mode

 

YP1

Component / RGB mode (processed as a

 

 

Y/PB/PR or RGB signals as set by this unit)

 

RG1

PC Mode

DAM

None

Screen mode select (toggle)

 

NORM

4 : 3

 

ZOOM

Zoom

 

FULL

16 : 9

 

JUST

Just

 

SELF

Panasonic Auto

With the power off, this display responds to PON command only.