Paradox Hellas S.A DGP2-640 manual User Options, Programming User Access Codes with the DGP2-648BL

Models: EVO96 DGP2-641BL DGP2-648BL DGP2-640 DGP2-641RB

1 36
Download 36 pages 18.97 Kb
Page 17
Image 17

LCD ICON LED

LCD ICON LED

Option [1]: Access Control

Option [2]: Can Disarm with Access Card

Option [3]: Extended Unlocked Period

Options [4] and [5]: Arming with Card

[4]ON, [5] OFF:Regular Arm

[4]OFF, [5] ON:Stay Arm

[4]and [5] ON:Force Arm

[4]and [5] OFF:Disable the Arming with Card feature

Option [6]:Add Tolerance Window to Schedule

Option [7]:Code Follows Schedule

Option [8]:Card to Unlock and Code to Disarm

13.Enter the Access Control card’s serial number within the brackets.

14.Press the [ENTER] button to save and exit.

6.6.2Programming User Access Codes with the DGP2-648BL

1.Enter your [SYSTEM MASTER CODE] or [ACCESS CODE] with Master feature.

2.Press the [0] key to enter the User Programming Menu. The area lights of areas assigned to your User Access Code and the PRG action light will flash.

3.Press the [ACC] key. The area lights of the areas assigned to your User Access Code and the ACCESS action light will illuminate. The PRG action light will continue to flash.

4.Enter a 3-digit number (002 to 999) you wish to program. The ACCESS action light will flash for an unused code. If the code is used, PRG action light and the first number of the code will illuminate. The ACCESS action and area light will turn off.

5.Enter a User Code. If you do not want to change an existing one, press the [U] key until you reach User Options. Your keypad will emit a Half Beep when it switches to User Options. Pre-existing options will illuminate.

6.Program the User Options by turning the options “ON” or “OFF”. Once the options are programmed, press the [U] key to reach the Area Assignment. Your keypad will emit a Half Beep when it switches to Area Assignment. Pre-existing assignments will illuminate.

7.Program the Area Assignment. Press the [V] key to return to User Options or press [ENTER] to save and exit. Your keypad will emit a Confirmation Beep to confirm the code’s acceptance.

6.7User Options

Options [1] and [2]: Master Feature

When option [1] is OFF, the User cannot program other users into the system. When option [1] is ON and option [2] is OFF, the user can program and modify user access codes (P.I.N. only) and User Labels.

When both options [1] and [2] are ON, the user has Full Master rights. The user can create or modify user access codes, User Options, User Access Control Options, Access Card Numbers, User Labels and Area Assignments according to their own programming. For example, if the Full Master User has access to area #1 and option [4] (Bypass) only, the Full Master user can only assign area #1 and option [4] to other users in the system.

Option [3]: Duress

When option [3] is ON, the Duress feature is enabled. This feature is used when someone forces a user to arm or disarm an area(s). By entering a user access code (P.I.N.) reserved for the Duress feature, the system will arm or disarm the area(s), and then send a silent alarm to the monitoring station.

14 EVO96

Page 17
Image 17
Paradox Hellas S.A DGP2-640 User Options, Programming User Access Codes with the DGP2-648BL, Option 3 Duress, 14 EVO96

EVO96, DGP2-641BL, DGP2-648BL, DGP2-640, DGP2-641RB specifications

Paradox Hellas S.A. is a prominent manufacturer of advanced security systems, and their product line includes an impressive range of alarm panels and modules. Among their offerings, the DGP2-641RB, DGP2-640, DGP2-648BL, DGP2-641BL, and the EVO96 stand out as key components with unique features and capabilities tailored to meet diverse security needs.

The DGP2-641RB is a versatile control panel that integrates seamlessly with various peripherals and detectors. This model is designed for both residential and commercial applications, providing outstanding performance through its intuitive user interface. It supports advanced networking options that facilitate easy installation and configuration, ensuring a hassle-free setup process.

The DGP2-640 is acclaimed for its robust reliability and efficiency. Featuring an advanced power management system, this control panel has the ability to handle a larger number of zones, making it ideal for extensive security systems. Additionally, it offers event logging capabilities, allowing users to review security events that have occurred, enhancing accountability and awareness.

Moving on to the DGP2-648BL, this model is engineered with customization in mind. Its multiple zone programming options cater to a wide array of environments, and the sleek black finish adds a modern touch to any installation. The DGP2-648BL is also designed to be compatible with Paradox's full range of wireless devices, ensuring that installation is not only flexible but also efficient.

The DGP2-641BL variant, similarly, focuses on delivering a mix of reliability and aesthetics. It sports an elegant design while retaining high functionality, offering users a satisfying blend of security and style. This model’s user-friendly interface provides easy access to all settings and options, making it a favorite among both technicians and end-users.

Finally, the EVO96 represents the pinnacle of innovation within Paradox Hellas S.A's lineup. This control panel is equipped with cutting-edge technologies, allowing for an unprecedented level of control and automation in security management. It boasts a high-capacity memory that stores extensive user data, facilitating tailored alarm configurations. The EVO96 is particularly noted for its capacity to integrate with smart home technologies, creating a comprehensive security ecosystem.

With these models, Paradox Hellas S.A. continues to push the boundaries of security technology, ensuring users have access to flexible, reliable, and innovative solutions that safeguard their properties.