Paradyne 3151 CSU manual

Models: 3151 CSU

1 14
Download 14 pages 42.96 Kb
Page 5
Image 5
5.Insert the CSU circuit card into the appropriate slot in the carrier. The power-up self-test begins.

5.Insert the CSU circuit card into the appropriate slot in the carrier. The power-up self-test begins.

495-14797

6.If you intend to use front panel emulation, connect the cable from the PC to Port 2 on the Auxiliary Backplane using the COM port adapter and COM-port-to-PC cable.

7.The Factory 1 configuration for ESF framing format and B8ZS line coding format is the default configuration and is appropriate for most networks. If this configuration does not work for you, try the Factory 2 configuration for D4 framing format and AMI line coding format. To further customize configuration options, refer to Changing Configuration Options in Chapter 3, Operation, and Appendix C, Configuration Options, in the ACCULINK 315x Channel Service Unit Operator's Guide.

8.During the power-up self-test, the FAIL LED flashes, then all LEDs blink twice. When the test is complete, verify that the CSU is functional by observing that the OK, NETWORK SIG, and DTE SIG LEDs are lit.

3

Page 5
Image 5
Paradyne 3151 CSU Insert the CSU circuit card into the appropriate slot in the carrier. The power-up self-test begins