Table 2. Network Interface Configuration Options (2 of 2)

Table 2. Network Interface Configuration Options (2 of 2)

Option

Factory 1

Factory 2

Comments/Description

 

 

 

 

 

Enab

N/A

Network-initiated PLB allows PLB to be

NET PLB:

 

Disab

 

controlled by FDL PLB messages.

 

 

 

 

 

 

 

 

 

 

N/A

62411

Enforces ONEs density protection per

 

 

BitStuff:

Part68

 

AT&T TR 62411, ANSI T1-403, and

 

 

 

FCC Part 68 Technical Publication.

 

 

Disab

 

 

 

 

 

 

 

 

AIS

AIS

 

 

 

 

 

 

One (Framed

One (Framed

Specifies the keep alive signal to send

 

All Ones)

All Ones)

KeepAlive:

to the network interface on a failure of

 

 

 

NetLp

NetLp

the DTE signal.

 

(Loopback of

(Loopback of

 

 

network signal)

network signal)

 

 

 

 

 

Yellow:

Enab

Enab

Transcodes and sends Yellow signal to

 

 

the network on receiving Yellow from

 

Disab

Disab

 

DTE.

 

 

 

 

 

 

 

Circuit Ident:

Edit

Edit

Specifies the transmission vendor's

 

 

 

Clear

Clear

circuit identifier.

 

 

 

 

 

 

 

Enab

Enab

Determines whether framing bits are

CRC PThru

 

 

Disab

Disab

passed to the DTE.

(Passthrough):

 

 

 

 

 

Table 3. General Configuration Options

Option

Factory 1

Factory 2

Comments/Description

 

 

 

 

 

Enab

Enab

Specifies whether user-initiated

Tst Timeout:

 

 

tests are limited by the Tst Duration

Disab

Disab

 

configuration option.

 

 

 

 

 

10

10

 

 

 

 

 

 

Up

Up

Specifies in minutes the duration of

Tst Duration:

 

 

Down

Down

user-initiated tests.

 

 

 

 

 

 

 

 

Save

Save

 

 

 

 

 

Table 4. User Interface Configuration Options (1 of 4)

Option

Factory 1

Factory 2

Comments/Description

 

 

 

 

 

Enab

Enab

Allows bypass of self-test on

Self-Test:

 

 

Disab

Disab

initialization.

 

 

 

 

 

 

 