Check the SDCP

3.Rotate the circuit pack lock(s) into the closed position, and tighten the screw.

Circuit

Pack

Lock

Closed

Circuit

Card

(Locked)

Guides

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Open

(Unlocked)

Latch495-14813

4.If the carrier is connected to power, the Power LED on the faceplate of the 3811Plus lights up. After several seconds the modem completes its power-up self-test in which all faceplate LEDs light up.

If the modem fails, or an alarm condition exists, the Alrm LED on the faceplate lights up or flashes. It may be possible to run a diagnostic self-test from the SDCP. See Test Branch in the COMSPHERE 3800Plus Modems User's Guide.

Return to the rear of the carrier and tighten the rear connector plate.

5.Connect an RS-232D DTE cable to the top connector of the rear connector plate. (The bottom connector is unused.)

6.Connect the other end of the cable to your DTE.

Check the SDCP

If an SDCP is installed, verify that the SDCP can be used to control the modem. Perform the following steps.

Carrier Slots 1–16

SDU

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

 

 

 

 

 

 

Select

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OK Alarm BckUp Test

EC

F1

F2

 

F3

 

 

 

COMSPHERE 3000

Select

Status

Keypad

LCD

Key

Indicators

 

Display

 

 

 

496-12348a-03

Procedure

1. Press the Select key on the SDCP. The cursor appears in the two-digit slot selection entry.

2.Press the Manual background key to position the cursor on the two-digit carrier selection entry.

3.Press the F1 () or F2 () key until the carrier number you want appears on the LCD.

The carrier number selection has a range of 1 to 8. With an SDU installed, a single SDCP can control up to eight carriers.

4.Press the Manual background key to position the cursor on the slot selection entry.

5.Press the F1 () or F2 () key until the slot number (1±16) you want appears on the LCD. (Ignore the AB designator that appears on the LCD since it is not applicable to the 3811Plus modem.)

The Front Panel LED on the modem's faceplate lights up.

6. Press the Select key to place the SDCP in direct communication with the selected modem.

The LCD displays the Top-Level menu for the selected modem.

7.Configure the modem as described in the following section, Select Factory Configuration Options.

3980-A2-GZ41-20

June 1998

7