concurrently; SAM2000G configurations cannot be saved independently. Once your IP DSLAM has been configured as desired (including the SAM2000G), settings can be flash uploaded (to a local file) through a Trivial File Transfer Protocol (TFTP) tool with a GET command and the following information:

6.1.2.1Backup

An IP DSLAM backup file records ALL management and port configurations.

ITEM

DATA NEEDED FOR BACKUP

EXAMPLE

Host Name

DSLAM_IP Address (xxx.xxx.xxx.xxx)

193.166.254.98

Remote Filename

NVR_BACKUP.BIN.[superuser password]

nvr_backup.bin.Password

Local Filename

user preference

dslam27_mum13_backup.bin

6.1.2.2Template

An IP DSLAM template file records all management and port configurations EXCEPT the MUM's IP Address.

ITEM

DATA NEEDED FOR BACKUP

EXAMPLE

Host Name

DSLAM_IP Address (xxx.xxx.xxx.xxx)

193.166.254.98

Remote Filename

NVR_CFG.BIN.[superuser password]

nvr_cfg.bin.Password

Local Filename

user preference

n2n_dslam12000_template.bin

Configuration files can also be flash downloaded FROM a local file TO an IP DSLAM, simply replace the GET command with a PUT command. Refer to your TFTP user manual for further instruction.

6.2LED Indications

LED

 

State

 

Indication

 

Additional Information

 

 

 

 

 

 

 

Power (PWR)

 

solid green

 

SAM2000G is

 

If the Power LED is not illuminated, it is unlikely

 

 

 

 

operational

 

that the SAM2000G-12 is receiving power, in

 

 

 

 

 

 

which case none of the LEDs will be illuminated.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SHDSL Link (Lk)

 

pulsing

 

SHDSL connection

 

The SHDSL link is operational and traffic is

 

 

green

 

is established and

 

flowing.

 

 

 

 

active

 

 

 

 

solid green

 

problematic SHDSL

 

A connection exists but there is indication of a

 

 

 

 

connection

 

problem with the SHDSL line.

 

 

no

 

no SHDSL

 

 

 

 

illumination

 

connection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

210-0000026 rev07

Page 8
Image 8
Paradyne SAM2000G-12 manual LED Indications, Data Needed for Backup Example