Configuring DIP Switch S1

Figure 2. Opening the Model 1052 case

Figure 1 on page 7 shows the orientation of the DIP switches in the “ON” and “OFF” positions.

Configuring DIP Switch S1

DIP switch S1 is where you configure the data rate, asynchronous or synchronous data format, transmit clock source. The following table sum- marizes default positions of DIP switches S1-1 through S1-8. Detailed descriptions of each switch follow the table.

S1 Summary Table

 

Position

Function

Factory Default

 

 

 

 

 

 

 

S1-1

Data Rate

Off

}

128K Sync

 

S1-2

Data Rate

Off

 

 

 

 

 

 

 

S1-3

Reserved

On

 

 

 

 

 

 

 

 

 

S1-4

Reserved

On

 

 

 

S1-5

Async/Sync Data Format

Off

 

 

 

 

 

 

 

 

 

S1-6

Tx Clock Source

On

}

Internal Clock

 

S1-7

Tx Clock Source

On

 

 

 

 

 

 

 

S1-8

Reserved

Off

 

 

 

 

 

 

 

 

Switches S1-1 and S1-2: Data Rate. Use switches S1-1 and S1-2 to

configure the asynchronous or synchronous data rate of the Model 1052.