Each setting represents one synchronous data rate and one asynchro- nous data rate.

S1-1

S1-2

Sync Data Rate

Async. Data Rate

 

 

 

 

Off

Off

kbps or 19.2 kbps

Reserved

On

On

32 kbps

Reserved

 

 

 

 

Off

On

56 kbps

Reserved

 

 

 

 

On

Off

64 kbps

Reserved

 

 

 

 

Off

Off

128 kbps (see note)

0–38.4 kbps

 

 

 

 

Note If the S2-1 switch is positioned in the OFF position, the 128 kbps sync data rate/0–38.4 kbps async data rate option is selected.

Switch S1-3.Must be set to the On position (Reserved).

S1-3

On

Setting

Reserved

Switch S1-4: Must be set to the ON position (Reserved).

S1-4

Setting

 

 

On

Reserved

Switch S1-5: Asynchronous/Sync Operation. Use Switch S1-5 to configure the Model 1052 for async/sync operation. Switch S1-5 must be set in the Off position. There is no other valid setting.

S1-5

Setting

 

 

Off

Async/Sync

Switches S1-6 and S1-7: System Clock Mode. Use Switches S1-6 and S1-7 to configure the 1052 for internal, or receive recover clock mode.

S1-6

S1-7

Clock Mode

Description

 

 

 

 

On

On

Internal

System clock generated internally

Off

On

External (DTE)

System clock derived from termi-

 

 

 

nal interface

 

 

 

 

On

Off

Receive Recover

System clock derived from the

 

 

 

received line signal

 

 

 

 

Off

Off

Hardware Reset

 

 

 

 

 