S1 SUMMARY TABLE

S1 SUMMARY TABLE

Position

Function

Factory Default

 

 

 

 

 

S1-1

Data Rate (Distance)

Off

}

 

S1-2

Data Rate (Distance)

Off

64 kbps (2x)

S1-3

Data Rate (Distance)

Off

 

S1-4

Data Rate (Distance)

On

 

S1-5

Clock Source

On

} Internal

S1-6

Clock Source

On

 

 

 

 

 

S1-7

DTE Control of RDL

Off

 

Disabled

 

 

 

 

 

S1-8

DTE Control of LAL

Off

 

Disabled

 

 

 

 

 

Switches S1-1 though S1-4: Data Rate (Distance)

Switches S1-1 through S1-4 are set in combination to determine two configuration parameters: synchronous data rate and maximum distance. Maximum distance is determined by the space between data packets in the communication stream between two Model 1180/35s. The "2X" setting doubles the space between data packets, when compared with the normal "1X" setting, and therefore doubles the maximum distance. A setting of "2X" facilitates communication distances up to 3 miles, and is available at certain data rates up to 64 kbps. A setting of "1X" supports communication at the normal distance of 1.5 miles.

S1-1

S1-2

S1-3

S1-4

Data Rate (Distance)

On

On

On

Off

2.4

(1X)

Off

On

On

On

9.6

(2X)

On

Off

On

Off

14.4

(1X)

On

Off

On

On

19.2

(2X)

Off

Off

On

Off

28.8

(1X)

Off

Off

On

On

38.4

(2X)

On

On

Off

On

48.0

(2X)

Off

On

Off

Off

56.0

(1X)

Off

Off

Off

On

64.0

(2X)

Off

On

On

Off

72.0

(1X)

Off

Off

Off

Off

128.0

(1X)

On

On

Off

Off

144.0

(1X)

Off

On

Off

On

192.0

(1X)

On

On

On

On

256.0

(1X)

S1-5 and S1-6: Clock Source

Switches S1-1 and S1-2 are set in combination to determine the source of the transmit clock for the Model 1180/35.

S1-5

S1-6

Setting

Off

Off

Received Recover Clock

On

Off

Internal Clock

Off

On

External Clock

On

On

Internal Clock

S1-7: DTE Control of RDL

The setting for switch S1-7 determines whether the V.35 DTE can activate the RDL test by raising pin L. If DTE Control of RDL is enabled, control from the front panel is disabled if there is no DTE connected.

NOTE: If DTE control is not avialable, set Switch S1-7 to off.

S1-7

Setting

On

DTE control of RDL enabled

Off

DTE control of RDL disabled

S1-8: DTE Control of LAL

The setting for switch S1-8 determines whether the V.35 DTE can activate the LAL test by raising pin N. If DTE Control of LAL is enabled, control from the front panel is disabled if there is no DTE connected.

NOTE: If DTE control is not available, set Switch S1-8 to off.

S1-8

Setting

On

DTE control of LAL enabled

Off

DTE control of LAL disabled