APPENDIX A

SPECIFICATIONS

A.1 LAN CONNECTION

Two shielded RJ-45, 10/100Base-T, IEEE 802.3 Ethernet

CopperLINK Connection: Shielded RJ-45

A.2 TRANSMISSION LINE

Two-wire unconditioned twisted pair.

A.3 COPPERLINK LINE RATE AND COPPERLINK DISTANCE

Line Rate: 15/15 Mbps, upstream/downstream. Additional five line rates are available via DIP switch settings.

Distance: 5,750 ft (1.7 km) at 1 Mbps upstream/4 Mbps downstream

Note Distances depend on selected line rate and line conditions. See Appendix D on page 19 for details.

A.4 LED STATUS INDICATORS

Power (Green)

CopperLINK: Link (Green)

Ethernet: Link (Green) & Activity (Flashing Green)

Remote (Green)

Local (Green)

A.5 POWER SUPPLY

External AC and DC options:

AC: 120 VAC, 220 VAC, and UI (120–240 VAC)

DC: 12 VDC, 24 VDC and 48 VDC

Power consumption: 860mA at 5V

A.6 TEMPERATURE RANGE

0–40°C

A.7 HUMIDITY

Up to 90% non-condensing.

A.8 DIMENSIONS

1.58H x 4.16W x 3.75D in. (10.6H x 4.1W x 8.8D cm)

16

Page 16
Image 16
Patton electronic 2151 Appendix a, LAN Connection, Transmission Line, Copperlink Line Rate and Copperlink Distance