An approved external power supply that incorporates a disconnect device must be used and positioned within easy reach of the operator’s position.

Caution

Connect the equipment to a 5 VDC source that is electri- cally isolated from the AC source. The 5 VDC source is to be reliably connected to earth.

Caution

External 48 VDC power supply

Input

Rated voltage: 36–60 VDC

Rated current: 0.25 A DC at nominal 48 VDC

3-pin locking connector, 3.5 mm pitch

Reverse polarity protection

Transient over-voltage protection, 100 VDC at 2 ms

Output

Rated voltage: 5 VDC ± 5%, 5W

Rated current; 1 A DC

6-inch cable terminated with 2.5 mm barrel plug, center positive

An approved external power supply that incorporates a disconnect device must be used and positioned within easy reach of the operator’s position.

Caution

Connect the equipment to a 36–60 VDC source that is electrically isolated from the AC source. The 36–60 VDC source is to be reliably connected to earth.

Caution