Switch S1-1: Local/Remote Configuration

Use switch S1-1 to configure the unit as Remote or Local in the Model 2174 pair.

Table 2: Local/Remote Unit Configuration

S1-1

Setting

 

 

ON

CPE/Remote

OFF

CO/Local

 

 

Switches S1-2 and S1-3: Symmetric/Asymmetric Operation

Use switches S1-2 and S1-3 to configure the CopperLink line rate type- and operation.

Table 3: Symmetric/Asymmetric Selection Chart

S1-2

S1-3

Setting

 

 

 

OFF

OFF

High-Speed “Symmetric”

OFF

ON

High-Speed “Asymmetric”

 

 

 

ON

OFF

Long-Range “Symmetric”

 

 

 

ON

ON

Long-Range “Asymmetric”

 

 

 

Note See Appendix D on page 20 for line rate distances.

Switch S1-5: General Protection (Signal to Noise Ratio)

Use switch S1-5 to configure line noise protection.

Table 4: Signal to Noise Ratio

S1-5

Setting

 

 

ON

6dB

OFF

9dB

 

 

6dB: Original line noise protection with 6dB SNR

9dB: Better line noise protection with SNR up to 9dB

15