Control Turn-Off Delay in "DATA" Switching Mode (SW23-1,2)

When configured to switch on DATA, switch SW23-1 and 2 set the Sub-Channel release time in clocks. The value selected is the number of clocks at the current baud rate that must occur without any data transitions on the Sub-Channel to indicate that Sub-Channel has completed its transmission and the 3060/V24 (CTS MD-V.24/TCB) can resume servicing the other Sub- Channels. The following table should be used to set this time period.

SW23-1 SW23-2 CLOCKS

ON

ON

16

 

 

 

ON

OFF

64

 

 

 

OFF

ON

256

 

 

 

OFF

OFF

2048

 

 

 

Switch on Data / Control (SW25-1,2,3,4,5,6)

Each sub-channel is independently selectable for switch on data or switch on an active interface control lead. Set SW25 pos 1 to OFF if sub-channel 1 switch on Data is required. Set pos 1 to ON if switch on interface control lead is desired. Position 2 thru 6 are associated with sub-channels 2 thru 6.

Internal Baud Rates (SW22-4,5,6,7)

Switch SW22-4, 5, 6 and 7 select the master clock rate when Internal Clock Source is selected on TX Clock Source or RX Clock Source. In addition the Fallback clock rate is also selected with this option. When Fallback clocking is required, the RX Clock Source and TX Clock Source should not be set to INTERNAL. Selecting CHAN 6 RXC allows Fallback clocks to originate from Sub-Channel 6 pin 17. The following table shows the available rates. If CHAN 6 RXC is selected, SW22-7 can be in either position.

SW22-4

SW22-5

SW22-6

Pos 7=ON

Pos 7=OFF

ON

ON

ON

76,800

57,600

 

 

 

 

 

OFF

ON

ON

38,400

28,800

 

 

 

 

 

ON

OFF

ON

19,200

14,400

 

 

 

 

 

OFF

OFF

ON

9,600

7,200

 

 

 

 

 

ON

ON

OFF

4,800

3,600

 

 

 

 

 

OFF

ON

OFF

2,400

1,800

 

 

 

 

 

ON

OFF

OFF

1,200

900

 

 

 

 

 

OFF

OFF

OFF

CHAN 6 RXC

 

 

 

 

 

SETUP & INSTALLATION

2-4

Page 12
Image 12
Patton electronic 3060/V24 manual OFF Chan 6 RXC

3060/V24 specifications

The Patton Electronic 3060/V24 is a cutting-edge digital communication solution that caters specifically to the need for versatile data transmission in various environments. This device is particularly well-suited for applications in enterprises, telecommunication networks, and industrial settings, delivering robust performance and reliability.

One of the standout features of the Patton Electronic 3060/V24 is its ability to support multiple protocols, making it highly adaptable to different communication standards. This flexibility ensures seamless integration into existing networks without the need for extensive changes or overhauls. Its support for synchronous and asynchronous data communication allows for efficient data transmission and enhances compatibility with legacy systems.

The device is equipped with advanced error correction technologies, ensuring the integrity and reliability of data during transmission over various mediums, including leased lines and IP networks. The use of sophisticated coding algorithms minimizes data loss and maximizes throughput, which is essential for businesses relying on critical communications.

In terms of characteristics, the Patton Electronic 3060/V24 boasts a user-friendly interface, simplifying configuration and management. With its intuitive web interface and SNMP support, network administrators can easily monitor performance metrics and troubleshoot issues in real-time. This ease of management helps reduce downtime and improves overall operational efficiency.

Moreover, the Patton Electronic 3060/V24 is designed with scalability in mind. It can easily expand to accommodate growing network demands, making it an ideal choice for organizations planning to future-proof their communication infrastructure. The device supports both copper and fiber connections, providing enhanced options for connectivity depending on the specific requirements of the deployment environment.

Power over Ethernet (PoE) capability further enhances its utility by allowing the device to receive power through the Ethernet cable, reducing the need for additional power outlets and simplifying installation in hard-to-reach areas.

In conclusion, the Patton Electronic 3060/V24 stands out as a versatile and reliable communication device that integrates advanced technologies to meet the demands of modern networks. Its flexibility, ease of management, and robust performance make it an ideal solution for businesses seeking to enhance their communication capabilities while ensuring reliability and efficiency.