TRANSTUBE® 110 EFX ESPECIFICACIONES
POWER AMP SECTION:
Rated power and load:
40 Watts (RMS) into 6 Ohms
Power @ clipping (typically): (5% THD, 1 kHz, 120 VAC line) 35 Watts (RMS) into 6 Ohms
Total harmonic distortion:
Less than 0.5% THD, 100 mW to 15 Watts (RMS), 100 Hz to 10 kHz
Power amp hum and noise @ nominal input level:
(20 Hz to 20 kHz, unweighted) Greater than 82 dB below rated power
Power Consumption:
75 Watts 50/60 Hz, 120 VAC
PREAMP SECTION:
The following specs are measured @ 1 kHz with the controls preset as follows: Channel select: CLEAN
EQ voicing switch: MODERN
Low, mid, and high: 5
Pre gain and post gain: 10
Efx adjust: OFF
Reverb: OFF
Delay: OFF
Volume (nominal level): 5
Volume (minimum level): 10
Preamp input (clean channel):
Impedance: High Z, 250 k Ohms
Nominal input level:
Minimum input level:
Effects send:
Output impedance: 1k Ohms
Nominal output Level:
Effects return:
Input impedance: 31 k Ohms
Nominal input level:
Headphone output:
Load impedance: 8 Ohms or greater
Nominal Power Output: 30 mW (RMS) into
8 Ohms
(Stereo jack, monaural signal disconnects internal speaker when phone plug is inserted.)
System Hum and noise @ nominal input level:
(20 Hz to 20 kHz, unweighted) Greater than 75 dB below rated power
Specifications are subject to change without notice.
23