Peavey VSX 26 manual Single VR112 Neo Cabinet w/118 Sub, Crossover settings, EQ after crossover

Models: 48 VSX 26 VR112

1 6
Download 6 pages 29.74 Kb
Page 1
Image 1
Setting up the

Setting up the

Versarray System

Processor Settings for Versarray 112Neo & Subs with VSX 26/48

(also Digitool/Prolinx)

Single VR112 Neo Cabinet w/118 Sub

Front End EQ (before the crossover section) = PEQ –2.0 dB @ 2k, bw= 0.6 (or use 1/3 octave band at 2 kHz set to –2.0 dB);

Infrasonic filtering: 24 dB/oct. LR @ 34 Hz)

Crossover settings:

Woofer= 24 dB/oct. LR @ 2.0 kHz, Tweeter= 24 dB/oct. Bessel @ 3.0 kHz, Woofer Polarity Normal, Tweeter Polarity Normal

Sub to Woofer Crossover: Sub= 24 dB/oct. LR @ 125Hz, Woofer= 24 dB/oct LR @ 100Hz, Sub Polarity Normal, Woofer Polarity Normal

EQ after crossover:

Woofer EQ = PEQ +1.5 dB @ 560 Hz, bw=0.5; PEQ -3.5 dB @ 850 Hz, bw=0.5 PEQ +3dB @ 115 Hz, bw= 2; PEQ –1.5 dB @ 2.2 kHz, bw=.7;

PEQ –2 dB @ 700 Hz, bw=3.0 Woofer Delay = 0.0 ms (none)

Tweeter EQ: PEQ –3 dB @ 2.7 kHz, bw= 0.7; PEQ +2.5 dB @ 4.6 kHz, bw= 1.0; PEQ +3.5 dB @ 16.5 kHz, bw=1.0 Tweeter Delay = 0.0 ms (none)

Sub EQ: PEQ +4.0 dB @ 50 Hz, bw= 0.7; PEQ -2.5 dB @ 100 Hz, bw= 0.5

Page 1
Image 1
Peavey VSX 26, 48 manual Single VR112 Neo Cabinet w/118 Sub, Crossover settings, EQ after crossover