Installation to Solid Concrete and Cinder Block

WARNING

When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet ASTM C-90 specifications. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid breaking out the back of the hole when entering a void or cavity.

Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.

Make sure that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.

2

Level and use wall plate as template to mark center

of holes. Drill two 5/16" (8 mm) dia. holes to a

minimum depth of 2.5" (64 mm). Insert anchors (B) in holes flush with wall. Place wall mount (A) over anchors and secure with wood screws (H). Make sure wall mount is level, and tighten all fasteners.

WARNING

Tighten screws so that wall plate is firmly attached,

 

but do not overtighten. Overtightening can damage

 

screws, greatly reducing their holding power.

Never tighten in excess of 80 in. • lb (9 N.M.).

Always attach concrete expansion anchors directly to

1

concrete

surface

B

Drill holes and insert anchors (B).

2

A

 

 

H

B

Place plate (A) over anchors (B) and secure with screws (H).

load-be aring concrete.

• Never attach concrete expansion anchors to concrete

covered with plaster, drywall, or other finishing mate-

rial. If mounting to concrete surfaces covered with a

finishing surface is unavoidable, the finishing surface

must be counterbored as shown below. Be sure con-

crete anchors do not pull away from concrete when

tightening screws. If plaster/drywall is thicker than

5/8" (16 mm), custom fasteners must be supplied by

installer. (not evaluated by UL)

3

Tighten all fasteners.

SOLID CONCRETE

CINDER BLOCK

 

 

INCORRECT

CORRECT

VIEW

wall

concrete

wall

concrete

 

plate

 

plate

 

 

 

 

 

CUTAWAY

 

plaster/

 

plaster/

 

drywall

 

drywall

 

 

 

 

B

WALL PLATE

H A

6 of 46

ISSUED: 01-15-08 SHEET #: 095-9282-2 06-12-09