5 of 24 ISSUED: 10-31-07 SHEET #: 202-9242-2 03-20-08
Visit Peerless website at www.peerlessmounts.com For customer care call 1-800-729-0307 or 708-865-8870
Installation to Solid Concrete or Cinder Block
1Make sure that wall plate (AA) is level, use it as a
template to mark four mounting holes. The top
mounting hole should be 2.5" (65 mm) above the
desired screen center as shown in fig. 1.1 on page 4.
Drill four 1/4" (6 mm) dia. holes to a minimum depth of
2.5" (65 mm). Insert anchors (EE) in holes flush with
wall as shown (right). Place wall plate over anchors
and secure with #14 x 2.5" screws (DD). Level, then
tighten all fasteners.
When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete
thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid
part of the block, generally 1" minimum from the side of the block. Cinder block must meet ASTM C-90 specifica-
tions. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to
avoid breaking out the back of the hole when entering a void or cavity.
Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
Make sure that the supporting surface will safely support the combined load of the equipment and all attached hard-
ware and components.
WARNING
CUTAWAY VIEW
INCORRECT
concrete
surface
1
3
2
EE
Drill holes and insert anchors (EE).
CORRECT
Place plate (AA) over anchors (EE) and secure with screws (DD).
Tighten all fasteners.
wall
plate
plaster/
dry wall
concrete wall plate concrete
plaster/
dry wall
AA
DD
AA
EE
DD
EE
solid concrete cinder block
Tighten screws so that wall plate is firmly attached,
but do not overtighten. Overtightening can damage
screws, greatly reducing their holding power.
Never tighten in excess of 80 in. • lb (9 N.M.).
WARNING
Always attach concrete anchors directly to load-
bearing concrete.
Never attach concrete anchors to concrete covered
with plaster, drywall, or other finishing material. If
mounting to concrete surfaces covered with a finishing
surface is unavoidable, the finishing surface must be
counterbored as shown below. Be sure concrete
anchors do not pull away from concrete when tighten-
ing screws. If plaster/drywall is thicker than 5/8",
custom fasteners must be supplied by installer.