SWITCH SETTINGS

WARNING: If you are using Pelco D-type or P-type control, your system may not operate if the baud rate and address switches are not set correctly. The switches are set at the factory at the defaults for Pelco D-type control (2400 baud and address 1).

Table A. Switch Settings for SW2

Special Systems

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch Number

1

2

3

4

5

6

7

8

9

10

 

 

 

 

 

 

 

 

 

 

 

AD-32 Preset System

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CM9502 Setting

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pelco Coaxitron Controller

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Third-Party Coaxial Control

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Third-Party Pelco P-type Control

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Serial Port Settings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch Number

1

2

3

4

5

6

7

8

9

10

 

 

 

 

 

 

 

 

 

 

 

RS422

 

 

 

OFF

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS485, 4-Wire

 

 

 

OFF

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS485, 2-Wire

 

 

 

ON

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pelco D or P Protocol Baud Rate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch Number

1

2

3

4

5

6

7

8

9

10

 

 

 

 

 

 

 

 

 

 

 

2400 Baud (Default for D-type Control)

 

 

 

 

 

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

4800 Baud (Default for P-type Control)

 

 

 

 

 

ON

OFF

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

9600 Baud

 

 

 

 

 

OFF

ON

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Video Cable Type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch Number

1

2

3

4

5

6

7

8

9

10

 

 

 

 

 

 

 

 

 

 

 

Coaxial Cable

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

UTP Cable

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dome Termination

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch Number

1

2

3

4

5

6

7

8

9

10

 

 

 

 

 

 

 

 

 

 

 

Terminated

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

Not Terminated

 

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

C3462M (9/09)

3

Page 3
Image 3
Pelco 27X, 35X Table A. Switch Settings for SW2, Switch Number RS422, RS485, 4-Wire, RS485, 2-Wire, Baud, UTP Cable