Installation
1Locate the center point of the mounting location and insert the compass tool. Draw a circle.
Cut the circle out of the ceiling.
2Attach the conduit fitting, safety chain bracket, and lock nut. Install a safety chain/cable (not supplied) that will support up to 16 pounds (7.3 kg).
3Open the hinged door to the back box. Push the tab lock towards the wall of the unit and lift the door open. Pull power, alarm/auxiliary, and network cable into the back box.
The following are the recommended maximum distances for 24 VAC applications and are calculated with a 10 percent voltage drop. (Ten percent is generally the maximum allowable voltage drop for
Total | 20 AWG | 18 AWG | 16 AWG | 14 AWG |
VA | (0.5 mm2) | (1.0 mm2) | (1.5 mm2) | (2.5 mm2) |
36 | 79 ft | 125 ft | 199 ft | 316 ft |
| (24 m) | (38 m) | (60 m) | (96 m) |
|
|
|
|
|
NOTE: Input power for the dome is 24 VAC only. Power consumption is 36 VA per dome. Use a 24 VAC transformer with a minimum of
36 VA per dome.
C2494M (12/05) | 3 |