8 C2403M-C (10/05)
Install Camera
1. Some indoor installations do not require a
heater. If the installation does not require a
heater, remove the heater board from the
camera assembly. To remove the heater press
on an end of the board.
2.
12 VDC operation only:
The camera is set for
24 VAC operation at the factory. For 12 VDC
operation remove the jumper from the 24 VAC
position and install it in the 12 VDC position.
3. If the heater is installed, plug the heater
connector from the camera into the
mating connector inside the base.
Plug the video connector from the camera into
the mating connector inside the base.
Turn on power to the camera and monitor.
4. If you have a varifocal lens, hold the assembly
in your hand and point the lens toward what
you want to view. Loosen the focal length and
focus locking screws. Adjust according to
scene detail. Retighten the screws.
WARNING:
Heater elements could be hot! When camera power is on, use caution when
adjusting the camera. This applies to all models.
HEATER
BOARD
24 VAC JUMPER
12 VDC JUMPER
VIDEO
CONNECTOR
HEATER
CONNECTOR
VIDEO
CONNECTOR
HEATER
CONNECTOR
5
0
4
504
E
FOCAL
LENGTH
FOCUS