8Pelco Manual C534M (2/98)

Table B. Relay/Jumper Reference Chart

Relay Board/Jumper GPI Relay Board/Jumper GPI
1 A/J1 1 (1) 17 C/J1 3 (1)
2 A/J2 1 (2) 18 C/J2 3 (2)
3 A/J3 1 (3) 19 C/J3 3 (3)
4 A/J4 1 (4) 20 C/J4 3 (4)
5 A/J5 1 (5) 21 C/J5 3 (5)
6 A/J6 1 (6) 22 C/J6 3 (6)
7 A/J7 1 (7) 23 C/J7 3 (7)
8 A/J8 1 (8) 24 C/J8 3 (8)
9 B/J1 2 (1) 25 D/J1 4 (1)
10 B/J2 2 (2) 26 D/J2 4 (2)
11 B/J3 2 (3) 27 D/J3 4 (3)
12 B/J4 2 (4) 28 D/J4 4 (4)
13 B/J5 2 (5) 29 D/J5 4 (5)
14 B/J6 2 (6) 30 D/J6 4 (6)
15 B/J7 2 (7) 31 D/J7 4 (7)
16 B/J8 2 (8) 32 D/J8 4 (8)

PIN 1

PIN 2

PIN 3 PIN 1

PIN 2

PIN 3

RELAY 4
RELAY 3
RELAY 2
RELAY 1
RELAY 5
RELAY 6
RELAY 7
RELAY 8
(TYPICAL FOR JUMPERS
ONE THROUGH FOUR) (TYPICAL FOR JUMPERS
FIVE THROUGH EIGHT)
J4
J3
J2
J1
J5
J6
J7
J8
NOTE: All straps are shown in the Normally Open Position.
1-2 = N/O
2-3 = N/C
1-2 = N/O
2-3 = N/C
P1 P2

Figure 5. Relay Card Jumper Locations