3.2.1 Setting the Start Address

3.2.1 Setting the Start Address

Each Pelco CM9760-IRC unit requires a six-bit start address. The start address is configured using the DIP switches on the communication card (see Figure 5: DIP switches). Each control card occupies one address space. An IRC unit occupies four address spaces (if there are only two control cards in the unit, it still occupies four address spaces).

The start address of an IRC unit is set with the DIP switches on the communication card per Table B.

 

 

 

Table B.

Start Addresses

 

 

 

 

 

 

 

 

 

 

DIP

DIP

DIP

DIP

DIP

DIP

Start Address

Start Address

Switch 8

Switch 7

Switch 6

Switch 5

Switch 4

Switch 3

(Binary)

(Decimal)

 

 

 

 

 

 

 

 

ON

ON

ON

ON

ON

ON

000000

0

 

 

 

 

 

 

 

 

ON

ON

ON

ON

ON

OFF

000001

1

 

 

 

 

 

 

 

 

ON

OFF

ON

ON

ON

ON

010000

16

 

 

 

 

 

 

 

 

ON

OFF

ON

ON

OFF

ON

010010

18

 

 

 

 

 

 

 

 

OFF

OFF

ON

ON

OFF

ON

110010

50

 

 

 

 

 

 

 

 

OFF

OFF

OFF

OFF

OFF

ON

111110

62

 

 

 

 

 

 

 

 

NOTE: It is necessary only to set the start address of the IRC as a whole. The start address of each control card in the unit is set by internal de- fault.

Unlike an IRC unit, a serial GPI occupies one address space. In the sample system outlined in Figure 3, the start addresses would set up according to Table C.

 

 

 

Table C.

Start Addresses

 

 

 

 

 

 

 

Device

 

Address

(Decimal)

Address (Binary)

 

 

 

 

 

 

 

Serial GPI

 

 

0

000000

Set via serial GPI communication

 

 

 

 

 

card DIP switches

 

 

 

 

 

 

IRC unit 1/control card 1

 

 

1

000001

Set via IRC unit 1 communication

 

 

 

 

 

card DIP switches

 

 

 

 

 

 

Control card 2

 

 

2

000010

Automatic internal default

 

 

 

 

 

 

Control card 3

 

 

3

000011

Automatic internal default

 

 

 

 

 

 

Control card 4

 

 

4

000100

Automatic internal default

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pelco Manual C544M (2/98)

9

Page 10
Image 10
Pelco C538M manual Setting the Start Address, Pelco Manual C544M 2/98, Table B, Start Addresses, Table C