Installation Instructions | CC3320 and CC4620 Cameras |
|
|
| LENS CONNECTION |
Fixed and manual iris lenses (for indoor use only) require no wiring connections.
Auto-Iris Lenses
Connections for
Direct Drive
Connect DD lenses to the female
++ = Lens positive supply
13 1 = Damp -
2 = Damp + |
V
= Lens ground
V = Video drive signal
|
| 3 | = Drive + |
2 | 4 | 4 | = Drive - |
DD Lens Connector
LENS SETUP PROCEDURES
For manual or fixed iris lenses set the EI switch and AGC switch to ON.
Switch the EI and AGC OFF. Refer to the lens instructions and adjust the lens for the optimum picture (video output level of 1V
Direct Drive Lenses
Where fitted, switch the EI and AGC OFF. Use an appropriate screwdriver to turn the lens level potentiometer (under the hinged flap) fully clockwise. Next, slowly adjust the potentiometer counterclockwise until the optimum picture is obtained (video output level of 1V
FOCUS ADJUSTMENT
The back focus adjustment screws are located on the top and side of the case at the front of the camera and should be adjusted using an appropriate screwdriver. Do not ‘over turn’ the back focus mechanism.
Fixed Lenses
Set the lens focus to infinity and view an image greater than 6.5 feet (2 m) away. Focus the image using the back focus screw. Set the lens focus as required.
Manual Iris Lenses
Open the iris fully and set the lens focus to infinity. View an image greater than 6.5 feet (2 m) away. Focus the image using the back focus screw. Set the lens focus and iris as required.
Auto-iris and Direct Drive Lenses
Fully open the iris by covering the lens with a suitable neutral density (ND) filter. Set the lens focus to infinity. View an image greater than 6.5 feet (2 m) away. Focus the image using the back focus screw. Remove the ND filter and set the lens focus as required.