SCAN SPEED

SPECTRA III

LANGUAGEENGLISH

<SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS>

ACK ALERT*

RESET CAMERA

CYCLE CAMERA POWER

REBOOT SYSTEM

EXIT

DOME SETTINGS

<CAMERA>

<MOTION> <POWER UP> <LINE SYNC> <PRESETS> <PATTERNS> <ZONES>

<TITLE TEXT> <ALERT>* <CLEAR> <PASSWORD>

BACK

EXIT

MOTION

AUTO FLIP

ON

PROPORTIONAL PAN

ON

PARK TIME (MINUTES)

0

PARK ACTION

NONE

SCAN SPEED (DEG/S)

25

LIMIT STOPS

ON

<SET MANUAL STOPS>

 

<CLEAR MANUAL STOPS>

 

<SET SCAN STOPS>

 

<CLEAR SCAN STOPS>

 

<SET AZIMUTH ZERO>

 

<CLEAR AZIMUTH ZERO>

 

BACK

 

EXIT

 

REFERENCE INFORMATION

 

MANUAL LIMITS SET

NO

SCAN LIMITS SET

NO

*This setting only applies to Pressurized Spectra III dome systems with software version 1.25 or higher.

SCAN SPEED

Scan speed is the degrees per second that the dome will pan when in a scan mode. Scan speed is adjustable from 1 to 40 degrees per second through the programming menu. The default setting is 25 degrees per second.

LIMIT STOPS

Limit stops are programmable stops that limit the pan range of the dome. There must be two limits, a left and a right, to define an area.

There are two types of limit stops:

MANUAL

A manual (joystick) pan operation stops when a limit stop is

 

reached.

SCAN

The dome reverses direction during random, frame, or auto

 

scanning when a limit stop is reached.

To set manual or scan stops:

1.Use the joystick to position the cursor beside SET MANUAL STOPS or SET SCAN STOPS.

2.Press Iris Open.

3.Follow the directions displayed on the monitor.

NOTE: In order for the manual or scan stops to work, the LIMIT STOPS setting must be ON.

To clear manual or scan stops:

1.Use the joystick to position the cursor beside CLEAR MANUAL STOPS or CLEAR SCAN STOPS.

2.Press Iris Open.

3.Follow the directions displayed on the monitor.

24

C2446M-E (11/05)

Page 24
Image 24
Pelco DD53TC16-X manual Scan Speed, Limit Stops