ADVANCED FEATURES

I/O INTERFACE

The DX9200 system can interface with the CM6800, CM9740, or CM9760 matrix switchers. It can integrate with the CM9760-DT, CM9760-ALM, and CM9760-REL.

CM9760-DT data translator translates the ASCII protocol to the P protocol of the CM9740/CM9760 matrix switchers.

Connect up to four CM9760-ALM alarm units to each DX9200 recorder.

Connect up to four CM9760-REL relay units to each DX9200 recorder.

I/O HANDLER

This application allows the installer to identify one additional external device—the CM9760 data translator, the CM9760-ALM alarm unit, or the CM9760-REL relay unit—to be connected to the COM port on the recorder. Each of the external devices can be shared across multiple recorders, but when programming to external devices, the programming only needs to be done on the recorder which is physically attached to the device.

I/O MANAGER

This application is used in conjunction with the I/O Handler to interface to:

the CM9760-ALM

the CM9760-REL

the CM9760-DT

Since these devices can be shared across multiple recorders across the network, the installer can identify alarm inputs 1-16 for recorder #1, alarm inputs 17-32 for recorder #2, and so on.

68

C634M-D (12/04)