Pelco manual Description, Installation, C1054M 6/99 ICIICISS45, Inter-Check Interface Cable

Models: ICIICISS45

1 4
Download 4 pages 27.35 Kb
Page 1
Image 1
C1054M (6/99)

C1054M (6/99)

ICIICISS45

Inter-Check®Interface Cable

®

300 W. Pontiac Way,

Clovis, CA 93612-5699

USA

In North America & Canada:

Tel (800) 289-9100

FAX (800) 289-9150

DataFAX (800) 289-9108

International Customers:

Tel (1-559) 292-1981

FAX (1-559) 348-1120

DataFAX (1-559) 292-0435

Pelco Online

http://www.pelco.com

NOTE: Both RJ-14 receptacles in the ICI1000WK wiring kit (sup- plied with the ICI1000S) must be connected at the black and yel- low terminals with 18 AWG two- conductor shielded cable (refer to the ICI1000S manual).

DESCRIPTION

The ICIICISS45 Inter-Check®interface cable is designed to connect an ICL/Fujitsu ISS45 sys- tem terminal to the Inter-Check®ICI1000S Series video text inserter. The interface cable con- sists of a printed circuit board, two DB25 connectors (male and female), and a 6-foot (1.8 m) data cable with an RJ-14 connector.

INSTALLATION

The following items are supplied:

1 ICIICISS45 Inter-Check®interface cable

1CN17-0111-0002 adapter, 25-pin (F) to 9-pin (M)

1CN17-0211-0001 adapter, 25-pin (M) to 9-pin (F)

Refer to Figure 1.

1.Turn off power to the ISS45 terminal.

2.If the ISS45 terminal is equipped with a customer pole display, unplug the cable connec- tor from port 3.

3.Plug the CN17-0111-0002 adapter (supplied) into the 9-pin port 3 of the ISS45 terminal.

4.Set the SW1 switch on the ICIICISS45 interface cable in the position toward the gray data cable.

5.Plug the ICIICISS45 interface cable connector into the CN17-0111-0002 adapter socket. If the ISS45 terminal is equipped with a customer pole display, go to step 6; if not, go to step 8.

6.Plug the CN17-0211-0001 adapter (supplied) into the ICIICISS45 interface cable socket (if the ISS45 terminal is equipped with a customer pole display).

7.Plug the customer pole display (if equipped) cable connector into the CN17-0211-0001 adapter.

8.Plug the ICIICISS45 data cable RJ-14 connector into the DATA IN receptacle of the ICI1000S video text inserter or into the ICI1000WK wiring kit receptacle.

9.Enable the customer pole display port if not previously being used.

10.Make certain all connections are tight. This completes the ICIICISS45 interface cable in- stallation. The ISS45 terminal must now be programmed by a qualified technician or dealer for the following parameters: 9600 baud, 8 bits, and parity off.

ADAPTER

 

ICIICISS45

ADAPTER

 

 

 

 

 

 

 

 

 

 

 

 

CUSTOMER POLE

DISPLAY CABLE

SW1

SWITCH

DATA CABLE

TO ICI1000S

TERMINAL

PORT 3

Figure 1. ICIICISS45 Inter-Check®Interface Cable

Page 1
Image 1
Pelco manual Description, Installation, C1054M 6/99 ICIICISS45, Inter-Check Interface Cable