Pelco Manual C342M-PSA (11/98) 13
Figure 7. Tilt Limit Adjustment
3
4
2
1
10
G
H
9
A
B
C
D
8
7
EF
6
5
2. Adjust the tilt limit stops.
Refer to Figure 7 for the location of the tilt limit stops (item 7). Turn the control
unit on and tilt the unit to the desired up position.
Move the up limit cam until it touches the limit switch actuator. Push the cam
against the actuator until it clicks, indicating that the limit switch has opened.
Apply Lock-Tite™ to the set screw (item H) and tighten the screw on the cam.
Operate the pan/tilt to the desired down position.
Move the down limit cam until it touches the limit switch actuator. Push the
cam against the actuator until it clicks, indicating that the limit switch has
opened. Apply Lock-Tite™ to the set screw (item H) and tighten the screw on
the cam.