24 Pelco Manual C585M-B (11/98)
7.0 SPECIFICATIONS

MPT8000 CONTROLLER

ELECTRICAL
Input Voltage
MPT8000CZ: 120 VAC, 60 Hz
MPT8000CZ/220: 230 VAC, 60 Hz
Power Consumption: 2.5 vA
Control Method: 15 pulse train (pulse width modulated)
Pulse Amplitude: 35 mA current loop
Connectors: One 3-contact terminal block
Fuse Protection
MPT8000CZ,
MPT8000CZ/220: One 1/16 A, 3AG, slow blow fuse
Power Cord: 3-wire grounded #18 AWG
Cable Requirements: Twisted pair, unshielded
Operating Distance: Control cable distances are approximate according to wire
used.
Wire Gauge Maximum Distance
22 AWG 5 miles (8 km)
20 AWG 10 miles (16 km)
CONTROLS
Power ON/OFF: Rocker switch
Pan/Tilt: 8-position joystick
ZOOM: Paddle switch, TELE/WIDE
FOCUS: Paddle switch, NEAR/FAR
IRIS: Paddle switch, OPEN/CLOSE
PAN AUTO/MAN: Paddle switch (latching function in receiver)
CAMERA ON/OFF: Paddle switch (non-functional; receiver permanently in ON
condition)
AUX 1, 2, 3, 4: Paddle switch (receiver provides +10 V, 20 mA output which
can be used as latching or momentary functions)
Pilot Lamp: Long life neon